Accuracy of Computer Diagnosis of Melanoma: A Quantitative Meta-analysis
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Recent developments in computer technology have raised expectations that fully automated diagnostic instruments will become available to diagnose cutaneous melanoma without the need of human expertise. OBJECTIVES: To critically review the contemporary literature on computer diagnosis of melanoma, evaluate the accuracy of such computer diagnosis, analyze the influence of study characteristics, and compare the accuracy of computer diagnosis of melanoma with human diagnosis. METHODS: Quantitative meta-analysis of published reports. DATA SOURCES: Eligible studies were identified by a MEDLINE search covering the period from January 1991 to March 2002, by manual searches of the reference lists of retrieved articles, and by direct communication with experts. RESULTS: Thirty studies with substantial differences in methodological quality were deemed eligible for meta-analysis. Five of these complied with the predetermined list of "good quality" requirements, but none met all methodological quality requirements. Ten of these studies compared the performance of computer diagnosis with human diagnosis. The diagnostic accuracy achieved with computer diagnosis was statistically not different from that of human diagnosis (log odds ratios, 3.36 vs 3.51; P =.80). The diagnostic performance of the computer diagnosis was better for studies that used dermoscopic images than for studies that used clinical images (log odds ratios, 4.2 vs 3.4; P =.08). Other study characteristics did not significantly influence the accuracy of the computer diagnosis. CONCLUSIONS: The computer diagnosis of melanoma is accurate under experimental conditions, but the practical value of automated diagnostic instruments under real-world conditions is currently unknown. We suggest minimum requirements for methodological quality in future experimental studies or, ideally, randomized controlled trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnostic accuracy of dermoscopy
Kittler, H., Pehamberger, H., Wolff, K., & Binder, M. (2002) · The Lancet Oncology · doi:10.1016/s1470-2045(02)00679-4 · Cited by 1,349
Cited by
Dermatologist-level classification of skin cancer with deep neural networks
Esteva, A., Kuprel, B., Novoa, R. A., Ko, J., Swetter, S. M., Blau, H. M., & Thrun, S. (2017) · Nature · doi:10.1038/nature21056 · Cited by 14,362
Artificial intelligence in digital pathology — new tools for diagnosis and precision oncology
Bera, K., Schalper, K. A., Rimm, D. L., Velcheti, V., & Madabhushi, A. (2019) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-019-0252-y · Cited by 1,698
Costs and benefits of health information technology.
Shekelle, P. G., Morton, S. C., & Keeler, E. B. (2006) · doi:10.23970/ahrqepcerta132 · Cited by 501
MED-NODE: A computer-assisted melanoma diagnosis system using non-dermoscopic images
Giotis, I., Molders, N., Land, S., Biehl, M., Jonkman, M. F., & Petkov, N. (2015) · Expert Systems with Applications · doi:10.1016/j.eswa.2015.04.034 · Cited by 364
Computerized analysis of pigmented skin lesions: A review
Korotkov, K., & Garcia, R. (2012) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2012.08.002 · Cited by 355
Metadata
- Authors
- Rosado, B.
- Venue
- Archives of Dermatology
- Publisher
- American Medical Association (AMA)
- Published
- 2003-03-01
- Volume
- 139
- Issue
- 3
- Pages
- 361
- ISSN
- 0003-987X (ISSN-L)
- OpenAlex
- W2068879084
- Cited by
- 121
- References
- 1
- FWCI
- 3.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of Computer Diagnosis of Melanoma: A Quantitative Meta-analysis. https://app.cochat.ai/papers/10.1001/archderm.139.3.361
- The paper
- Rosado, B. (2003). Accuracy of Computer Diagnosis of Melanoma: A Quantitative Meta-analysis. Archives of Dermatology. https://doi.org/10.1001/archderm.139.3.361
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.