Complications associated with thoracentesis. A prospective, randomized study comparing three different methods
Abstract
To determine what role the technique plays in complications associated with thoracentesis performed by physicians in training, we undertook a prospective study of thoracentesis in the medical service at our institution in which the sampling method was randomized among needle, needle with catheter, and needle with direct sonographic guidance. Fifty-two spontaneously breathing, cooperative patients with free-flowing effusions obliterating more than half of the hemidiaphragm on an upright, posteroanterior chest roentgenogram were randomized. When we analyzed those complications that were potentially life-threatening (eg, pneumothorax) and/or placed patients at increased risk for further morbidity (eg, pneumothorax, dry tap, inadequate tap), the sonography-guided method was associated with significantly fewer serious complications (0 of 19) than the needle-catheter (9 of 18) or needle-only methods (5 of 15). The sonography-guided method was associated with fewer pneumothoraces (0 of 19) than the needle-catheter (7 of 18) or needle-only methods (3 of 15). The difference between needle-catheter and needle-only methods was not significant. From our results, we conclude that the method by which thoracentesis was performed significantly influenced the spectrum and frequency of complications, and the sonography-guided method was the safest.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Establishing the Diagnosis of Lung Cancer
Rivera, M. P., Mehta, A. C., & Wahidi, M. M. (2013) · Chest · doi:10.1378/chest.12-2353 · Cited by 1,089
Hooper, C., Lee, Y. C. G., Maskell, N., & on behalf of the BTS Pleural Guideline Group (2010) · Thorax · doi:10.1136/thx.2010.136978 · Cited by 824
Pleural procedures and thoracic ultrasound: British Thoracic Society pleural disease guideline 2010
Havelock, T., Teoh, R., Laws, D., Gleeson, F., & on behalf of the BTS Pleural Disease Guideline Group (2010) · Thorax · doi:10.1136/thx.2010.137026 · Cited by 794
O’Grady, N. P., Barie, P. S., Bartlett, J. G., Bleck, T., Carroll, K., Kalil, A. C., Linden, P., Maki, D. G., Nierman, D., Pasculle, W., et al. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e318169eda9 · Cited by 600
Frankel, H. L., Kirkpatrick, A. W., Elbarbary, M., Blaivas, M., Desai, H., Evans, D., Summerfield, D. T., Slonim, A., Breitkreutz, R., Price, S., et al. (2015) · Critical Care Medicine · doi:10.1097/ccm.0000000000001216 · Cited by 494
Metadata
- Authors
- Grogan, D. R.
- Venue
- Archives of Internal Medicine
- Publisher
- American Medical Association
- Published
- 1990-04-01
- Volume
- 150
- Issue
- 4
- Pages
- 873-877
- ISSN
- 0003-9926 (ISSN-L)
- OpenAlex
- W1982712387
- Cited by
- 227
- References
- 0
- FWCI
- 5.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Complications associated with thoracentesis. A prospective, randomized study comparing three different methods. https://app.cochat.ai/papers/10.1001/archinte.150.4.873
- The paper
- Grogan, D. R. (1990). Complications associated with thoracentesis. A prospective, randomized study comparing three different methods. Archives of Internal Medicine. https://doi.org/10.1001/archinte.150.4.873
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.