Aneroid sphygmomanometers. An assessment of accuracy at a university hospital and clinics
The DOI matches its OpenAlex record.
Abstract
Defects of aneroid sphygmomanometers are a source of error in blood pressure measurement. We inspected 230 aneroid sphygmomanometers for physical defects and compared their accuracy against a standard mercury manometer at five different pressure points. An aneroid sphygmomanometer was defined as intolerant if it deviated from the mercury manometer by greater than +/- 3 mm Hg at two or more of the test points. The three most common physical defects were indicator needles not pointing to the "zero box," cracked face plates, and defective tubing. Eighty (34.8 of the 230 aneroid sphygmomanometers were determined to be intolerant with the greatest frequency of deviation seen at pressure levels of 150 mm Hg or greater. We recommend that aneroid manometers be inspected for physical defects and calibrated for accuracy against a standard mercury manometer at 6-month intervals to prevent inaccurate blood pressure measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Human blood pressure determination by sphygmomanometry.
Perloff, D., Grim, C., Flack, J., Frohlich, E. D., Hill, M., McDonald, M., & Morgenstern, B. Z. (1993) · Circulation · doi:10.1161/01.cir.88.5.2460 · Cited by 1,591
Carroli, G., Rooney, C., & Villar, J. (2001) · Paediatric and Perinatal Epidemiology · doi:10.1046/j.1365-3016.2001.0150s1001.x · Cited by 622
Principles and Techniques of Blood Pressure Measurement
Ogedegbe, G., & Pickering, T. (2010) · Cardiology Clinics · doi:10.1016/j.ccl.2010.07.006 · Cited by 554
Kallioinen, N., Hill, A., Horswill, M. S., Ward, H. E., & Watson, M. O. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001197 · Cited by 357
Blood Pressure Assessment in Adults in Clinical Practice and Clinic-Based Research
Muntner, P., Einhorn, P. T., Cushman, W. C., Whelton, P. K., Bello, N. A., Drawz, P. E., Green, B. B., Jones, D. W., Juraschek, S. P., Margolis, K. L., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.069 · Cited by 199
“However, aneroid manometers are easily damaged and require frequent recalibration to ensure their measurement accuracy (13).”
Background
Metadata
- Authors
- Bailey, R. H.
- Venue
- Archives of Internal Medicine
- Publisher
- American Medical Association
- Published
- 1991-07-01
- Volume
- 151
- Issue
- 7
- Pages
- 1409-1412
- ISSN
- 0003-9926 (ISSN-L)
- OpenAlex
- W2144356119
- Cited by
- 57
- References
- 0
- FWCI
- 0.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Aneroid sphygmomanometers. An assessment of accuracy at a university hospital and clinics. https://app.cochat.ai/papers/10.1001/archinte.151.7.1409
- The paper
- Bailey, R. H. (1991). Aneroid sphygmomanometers. An assessment of accuracy at a university hospital and clinics. Archives of Internal Medicine. https://doi.org/10.1001/archinte.151.7.1409
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.