BACKGROUND: Screening for non-insulin-dependent diabetes mellitus (NIDDM) can be useful in clinical practice and in epidemiologic and genetic studies, but the available information for choosing between screening methods is limited. In this study, characteristics of several screening tests for NIDDM were compared. METHODS: Among Pima Indians participating in an epidemiologic study, the sensitivity and specificity for detecting NIDDM of fasting plasma glucose (FPG) levels and two measures of glycated hemoglobin (HbA1 or HbA1c) were compared in 2092 fasting subjects. Glycated hemoglobin, quantitative glycosuria, and dipstick glycosuria were compared in 237 nonfasting subjects. Diabetes was diagnosed using an oral glucose tolerance test if the 2-hour postload venous plasma glucose concentration was 11.1 mmol/L (200 mg/dL) or greater. The area under the relative operating characteristic curve was used to compare tests. RESULTS: In fasting subjects, the sensitivity for detecting diabetes with 98% specificity was 78.8% for HbA1 level of 7.5% or greater, 80.3% for HbA1c level of 6.3% or greater, and 88.0% for FPG level of 6.83 mmol/L (123 mg/dL) or greater. By relative operating characteristic analysis, there were no significant differences between FPG and HbA1c, but FPG was significantly more sensitive than HbA1. In nonfasting subjects the sensitivity at 98% specificity was 92.9% for HbA1 level of 7.3% or greater, 80.6% for quantitative urine glucose level of 1.94 mmol/L (35 mg/dL) or greater, and 64.3% for trace or greater of dipstick glycosuria. The area under the relative operating characteristic curve was significantly greater for glycated hemoglobin than for either measure of glycosuria. CONCLUSIONS: Although FPG has the best screening properties, HbA1c, HbA1, and quantitative urine glucose also provide high specificity and approximately 80% sensitivity in detecting NIDDM. The choice of a particular method could depend on cost, convenience, and availability.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

OpenAlex · 10.1001/archinte.153.18.2133

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Hanson, R. L.
Venue
Archives of Internal Medicine
Publisher
American Medical Association
Published
1993-09-27
Volume
153
Issue
18
Pages
2133-2133
ISSN
0003-9926 (ISSN-L)
OpenAlex
W2085428344
Cited by
93
References
5
FWCI
2.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).