CoChat

Does the Computerized Display of Charges Affect Inpatient Ancillary Test Utilization?

David Westfall Bates · 1997 · Archives of Internal Medicine
Cited by 116

The DOI matches its OpenAlex record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The computerized display of charges for ancillary tests in outpatients has been found to affect physician-ordering behavior, but this issue has not been studied in inpatients. OBJECTIVE: To assess whether the computerized display of charges for clinical laboratory or radiological tests affected physician-ordering behavior. PATIENTS AND METHODS: Two prospective controlled trials, randomized by patient, were performed. Each trial included all medical and surgical inpatients at 1 large teaching hospital during 4 and 7 months: 3536 intervention and 3554 control inpatients in the group with clinical laboratory tests, and 8728 intervention and 8653 control inpatients in the group with radiological tests. The intervention consisted of the computerized display of charges for tests at the time of ordering. MAIN OUTCOME MEASURES: The number of clinical laboratory and radiological tests ordered per admission and the charges for these tests. RESULTS: For the clinical laboratory tests, during a 4-month study period, patients in the intervention group had 4.5% fewer tests ordered, and the total charges for these tests were 4.2% lower, although neither difference was statistically significant. Compared with historical controls from the same 4-month period a year before, the charges for the tests per admission had decreased 13.3%, but the decrease was temporally correlated with a restriction of future ordering of tests, and not with the introduction of the display of charges. For the radiological tests, during a 7-month period, the intervention group had almost identical numbers of tests ordered and charges for these tests. CONCLUSIONS: The computerized display of charges had no statistically significant effect on the number of clinical laboratory tests or radiological procedures ordered or performed, although small trends were present for clinical laboratory tests. More intensive interventions may be needed to affect physician test utilization.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

OpenAlex · 10.1001/archinte.157.21.2501

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 116

Metadata

Authors
Bates, D. W.
Venue
Archives of Internal Medicine
Publisher
American Medical Association
Published
1997-11-24
Volume
157
Issue
21
Pages
2501-2501
ISSN
0003-9926 (ISSN-L)
OpenAlex
W2115830376
Cited by
116
References
1
FWCI
5.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.