The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Population-Based Study of the Effectiveness of Inferior Vena Cava Filter Use Among Patients With Venous Thromboembolism
Open accessAbstract
BACKGROUND: There are few population-based data regarding the effectiveness of inferior vena cava filter use in the prevention of symptomatic pulmonary embolism. OBJECTIVE: To determine the 1-year cumulative incidence of rehospitalization for venous thrombosis or pulmonary embolism among patients with thromboembolism treated with a vena cava filter compared with the incidence in a control population with thromboembolism. PATIENTS AND METHODS: Population-based retrospective analysis of linked hospital discharge abstracts in California. From January 1, 1991, through December 30, 1995, 3632 patients were treated with a filter and 64,333 controls were admitted with a principal diagnosis of venous thromboembolism. RESULTS: Filter-treated patients had significantly greater comorbidity, with a higher frequency of previous pulmonary embolism, recent major bleeding, malignant neoplasm, and stroke. Patients who initially manifested pulmonary embolism were significantly more likely to be rehospitalized for pulmonary embolism than patients with an initial diagnosis of venous thrombosis alone, among filter-treated patients (relative risk, 6.72; 95% confidence interval, 3.61-12.49) and controls (relative risk, 5.30; 95% confidence interval, 4.61-6.10). Risk-adjusted proportional hazards modeling showed no significant difference between filter-treated patients and controls in the relative hazard of rehospitalization for pulmonary embolism. However, filter placement was associated with a significantly higher relative hazard of rehospitalization for venous thrombosis among patients who initially manifested pulmonary embolism (relative hazard, 2.62; 95% confidence interval, 2.09-3.29), but not among those who presented with venous thrombosis (relative hazard, 1.14; 95% confidence interval, 0.92-1.43). CONCLUSIONS: Insertion of a vena cava filter was not associated with a significant reduction in the 1-year incidence of rehospitalization for pulmonary embolism. Use of a filter was associated with a higher incidence of rehospitalization for venous thrombosis, but only among patients who initially manifested pulmonary embolism. A prospective clinical study is needed to determine the efficacy of filter use among patients with pulmonary embolism who do not meet strict guidelines for insertion of a vena cava filter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Levine, M. N., Hirsh, J., Gent, M., Turpie, A. G., Weitz, J., Ginsberg, J., Geerts, W., LeClerc, J., Neemeh, J., Powers, P., et al. (1995) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1649783 · Cited by 353
Cited by
The Epidemiology of Venous Thromboembolism
White, R. H. (2003) · Circulation · doi:10.1161/01.cir.0000078468.11849.66 · Cited by 2,310
Self-citationJaff, M. R., McMurtry, M. S., Archer, S. L., Cushman, M., Goldenberg, N., Goldhaber, S. Z., Jenkins, J. S., Kline, J. A., Michaels, A. D., Thistlethwaite, P., et al. (2011) · Circulation · doi:10.1161/cir.0b013e318214914f · Cited by 2,229
Self-citationAntithrombotic Therapy for Venous Thromboembolic Disease
Kearon, C., Kahn, S. R., Agnelli, G., Goldhaber, S., Raskob, G. E., & Comerota, A. J. (2008) · Chest · doi:10.1378/chest.08-0658 · Cited by 1,996
Natural History of Venous Thromboembolism
Kearon, C. (2003) · Circulation · doi:10.1161/01.cir.0000078464.82671.78 · Cited by 1,048
The PREPIC Study Group (2005) · Circulation · doi:10.1161/circulationaha.104.512834 · Cited by 931
British Thoracic Society guidelines for the management of suspected acute pulmonary embolism
(2003) · Thorax · doi:10.1136/thorax.58.6.470 · Cited by 686
Kyrle, P. A., & Eichinger, S. (2005) · The Lancet · doi:10.1016/s0140-6736(05)71880-8 · Cited by 616
A prospective registry of 5,451 patients with ultrasound-confirmed deep vein thrombosis
Goldhaber, S. Z., & Tapson, V. F. (2004) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2003.09.057 · Cited by 480
British Thoracic Society guidelines for the management of suspected acute pulmonary embolism
Campbell, I. A., Fennerty, A., & Miller, A. C. (2005) · PULMONOLOGIYA · doi:10.18093/0869-0189-2005-0-4-19-39 · Cited by 458
Kaufman, J. A., Kinney, T. B., Streiff, M. B., Sing, R. F., Proctor, M. C., Becker, D., Cipolle, M., Comerota, A. J., Millward, S. F., Rogers, F. B., et al. (2006) · Journal of Vascular and Interventional Radiology · doi:10.1097/01.rvi.0000203418-39769.0d · Cited by 413
Acute Pulmonary Embolism: Part I: Epidemiology, Pathophysiology, and Diagnosis
Goldhaber, S. Z., & Elliott, C. G. (2003) · Circulation · doi:10.1161/01.cir.0000097829.89204.0c · Cited by 406
Update on Inferior Vena Cava Filters
Kinney, T. B. (2003) · Journal of Vascular and Interventional Radiology · doi:10.1097/01.rvi.0000064860.87207.77 · Cited by 355
Goldhaber, S. Z. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16004-2 · Cited by 348
Twenty-one-Year Trends in the Use of Inferior Vena Cava Filters
Stein, P. D., Kayali, F., & Olson, R. E. (2004) · Archives of Internal Medicine · doi:10.1001/archinte.164.14.1541 · Cited by 329
Spyropoulos, A. C., & Lin, J. (2007) · Journal of Managed Care Pharmacy · doi:10.18553/jmcp.2007.13.6.475 · Cited by 328
Economic burden of deep-vein thrombosis, pulmonary embolism, and post-thrombotic syndrome
MacDougall, D. A., Feliu, A. L., Boccuzzi, S. J., & Lin, J. (2006) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp060388 · Cited by 300
Epidemiology of venous thromboembolism in 9489 patients with malignant glioma
Semrad, T. J., O'Donnell, R., Wun, T., Chew, H., Harvey, D., Zhou, H., & White, R. H. (2007) · Journal of Neurosurgery · doi:10.3171/jns.2007.106.4.601 · Cited by 284
Self-citationLópez, J. A., Kearon, C., & Lee, A. Y. Y. (2004) · Hematology · doi:10.1182/asheducation-2004.1.439 · Cited by 272
Risk assessment for recurrent venous thrombosis
Kyrle, P. A., Rosendaal, F. R., & Eichinger, S. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60962-2 · Cited by 261
Clinical review: inferior vena cava filters in the age of patient-centered outcomes
Wang, S. L., & Lloyd, A. J. (2013) · Annals of Medicine · doi:10.3109/07853890.2013.832951 · Cited by 54
Postthrombotic syndrome in relation to vena cava filter placement: a systematic review
Fox, M. A., & Kahn, S. R. (2008) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2008.03.022 · Cited by 45
Metadata
- Authors
- White, R. H., Zhou, H., Kim, J., & Romano, P. S.
- Venue
- Archives of Internal Medicine
- Publisher
- American Medical Association (AMA)
- Published
- 2000-07-10
- Volume
- 160
- Issue
- 13
- Pages
- 2033
- ISSN
- 0003-9926 (ISSN-L)
- OpenAlex
- W2103228243
- Cited by
- 195
- References
- 1
- FWCI
- 6.84
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.