Management of Severe Hypokalemia in Hospitalized Patients: A Study of Quality of Care Based on Computerized Databases
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: While administrative databases are used to assess general indicators of quality of care, a detailed audit of the process of clinical care usually requires review of hospital medical records. OBJECTIVE: To evaluate the feasibility of assessing the management of severe hypokalemia using computerized administrative and laboratory databases. METHODS: The study included all patients hospitalized in 1997 who experienced serum potassium levels of less than 3.0 mmol/L at Hadassah University Hospital, Jerusalem, Israel, a tertiary care center. Using the computerized databases, we measured the following: (1) whether a subsequent serum potassium test was performed, (2) time to the subsequent test and to normalization of the serum potassium level, (3) achievement of normokalemia, and (4) in-hospital mortality. In a random subsample of 100 patients, these measures were compared with the blinded assessment of the quality of medical management of hypokalemia, as determined from medical records, using predetermined criteria for adequate management. RESULTS: The computerized databases revealed that severe hypokalemia occurred in 866 patients (2.6% of the yearly hospitalizations): 55 patients (6.4%) had no subsequent serum potassium levels measured, and 260 (30.0%) were discharged from the hospital with a subnormal potassium level. The mean time to a subsequent test was 20 hours, and to normokalemia, 50 hours; both intervals varied by department. In-hospital mortality was 20.4%, or 10-fold that of the entire hospitalized population. A review of hospital medical records revealed inadequate clinical management of hypokalemia in 24%, which was associated with nonperformance of a subsequent test (likelihood ratio, 8.4), failure to normalize the serum potassium level (likelihood ratio, 4.2), discharge from the hospital with a subnormal potassium level (likelihood ratio, 2.1), and in-hospital death (likelihood ratio, 2.5), all of which could be determined by the computerized databases. CONCLUSIONS: The computerized laboratory database is useful in ascertaining the prevalence of severe hypokalemia and in assessing shortcomings in its management. Databases can be used to derive valid and efficient measures of the quality of the clinical management of electrolyte disorders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of Computer-Based Alerts on the Treatment and Outcomes of Hospitalized Patients
Rind, D. M. (1994) · Archives of Internal Medicine · doi:10.1001/archinte.1994.00420130107014 · Cited by 323
Cited by
Clase, C. M., Carrero, J.-J., Ellison, D. H., Grams, M. E., Hemmelgarn, B. R., Jardine, M. J., Kovesdy, C. P., Kline, G. A., Lindner, G., Obrador, G. T., et al. (2020) · Kidney International · doi:10.1016/j.kint.2019.09.018 · Cited by 498
Potassium disorders—clinical spectrum and emergency management
Alfonzo, A. V. M., Isles, C., Geddes, C., & Deighan, C. (2006) · Resuscitation · doi:10.1016/j.resuscitation.2005.11.002 · Cited by 218
Pathophysiology and management of hypokalemia: a clinical perspective
Unwin, R. J., Luft, F. C., & Shirley, D. G. (2011) · Nature Reviews Nephrology · doi:10.1038/nrneph.2010.175 · Cited by 216
“Around 3% of unselected hospitalized patients may be hypokalemic on admission to the clinic”
BackgroundIncidence and determinants of hyperkalemia and hypokalemia in a large healthcare system
Nilsson, E., Gasparini, A., Ärnlöv, J., Xu, H., Henriksson, K. M., Coresh, J., Grams, M. E., & Carrero, J. J. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.07.035 · Cited by 211
Pasquel, F. J., Tsegka, K., Wang, H., Cardona, S., Galindo, R. J., Fayfman, M., Davis, G., Vellanki, P., Migdal, A., Gujral, U., et al. (2020) · Diabetes Care · doi:10.2337/dc19-1168 · Cited by 161
Lin, J. J., & Moore, C. (2011) · American Journal of Medical Quality · doi:10.1177/1062860610385333 · Cited by 12
Moore, C., Saigh, O., Trikha, A., & Lin, J. J. (2008) · Journal of Patient Safety · doi:10.1097/pts.0b013e31818d1ca4 · Cited by 12
Lin, Y.-Y., & Hsieh, Y.-S. (2021) · Cureus · doi:10.7759/cureus.15880 · Cited by 6
“It is associated with an increased risk of arrhythmia in patients and as much as a 10-fold increase in all-cause mortality [4].”
Background
Metadata
- Authors
- Paltiel, O., Salakhov, E., Ronen, I., Berg, D., & Israeli, A.
- Venue
- Archives of Internal Medicine
- Publisher
- American Medical Association (AMA)
- Published
- 2001-04-23
- Volume
- 161
- Issue
- 8
- Pages
- 1089
- ISSN
- 0003-9926 (ISSN-L)
- OpenAlex
- W2091341393
- Cited by
- 78
- References
- 1
- FWCI
- 1.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.