Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 192

The DOI matches its Crossref record.

Simplification of the Diagnostic Management of Suspected Deep Vein Thrombosis

Kraaijenhagen, Roderik A., Piovella, Franco, Bernardi, Enrico, Verlato, Fabio, Beckers, Erik A. M., Koopman, Maria M. W., Barone, Marisa, Camporese, Giuseppe, Potter van Loon, Bert Jan, Prins, Martin H., Prandoni, Paolo, Büller, Harry R. · 2002 · Archives of Internal Medicine

Abstract

BACKGROUND: The standard diagnostic approach in patients with suspected deep vein thrombosis is to repeat the compression ultrasonography after 1 week in all patients with an initial normal result. We hypothesized that a normal finding of a D-dimer assay safely obviates the need for repeated ultrasonography. In addition, we evaluated the potential value of a pretest probability assessment for this purpose. METHODS: At presentation, consecutive outpatients with suspected thrombosis underwent independent assessment by means of ultrasonography of the proximal veins, a whole-blood D-dimer assay, and a pretest clinical model. Patients with normal ultrasonographic findings and an abnormal D-dimer assay result were scheduled for repeated ultrasonography. We evaluated the incidence of symptomatic venous thromboembolic complications during a 3-month follow-up, and the value of clinical pretest probability with ultrasonography or D-dimer assay in scenario analyses. RESULTS: We studied 1756 patients with prevalence of thrombosis of 22%. At entry, results of the D-dimer assay and ultrasonography were normal in 828 patients (47%). Of these, 6 returned with confirmed symptomatic venous thromboembolism (complication rate, 0.7%; 95% confidence interval [CI], 0.3%-1.6%). Repeated ultrasonography was avoided in 61% of the patients with an initial normal test result. Scenario analyses disclosed that the complication rate was 1.6% (95% CI, 0.8%-2.6%) in those with a low clinical pretest probability and a normal result of ultrasonography at referral, whereas this figure was 1.8% (95% CI, 0.9%-3.3%) in patients with a low clinical probability result and a normal result of the D-dimer assay at referral. CONCLUSIONS: It is safe to withhold repeated ultrasonography in patients with suspected deep vein thrombosis who have normal results of ultrasonograpy and the SimpliRED D-dimer assay at presentation. The combination of a low clinical pretest probability with a normal result of compression ultrasonography or the D-dimer assay appears to be equally safe in refuting the diagnosis of deep vein thrombosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archinte.162.8.907

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Kraaijenhagen, R. A., Piovella, F., Bernardi, E., Verlato, F., Beckers, E. A. M., Koopman, M. M. W., Barone, M., Camporese, G., Potter van Loon, B. J., Prins, M. H., Prandoni, P., & Büller, H. R.
Venue
Archives of Internal Medicine
Published
2002-04-22
Volume
162
Issue
8
Pages
907
ISSN
0003-9926 (ISSN-L)
OpenAlex
W2166615708
Cited by
192
References
0
FWCI
13.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.