Effects of Health Maintenance Organization Coverage of Self-monitoring Devices on Diabetes Self-care and Glycemic Control
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Increasingly, government mandates require insurance coverage of blood glucose monitors and test strips for patients with type 1 and type 2 diabetes. No data exist on the effects of such coverage on self-monitoring of blood glucose (SMBG), medication compliance, or blood glucose control. We evaluated whether a policy providing free blood glucose monitors increased SMBG and whether initiating SMBG was associated with increased regularity of medication use and improved glucose control (hemoglobin A(1c) [HbA(1c)] level). METHODS: Using interrupted time-series analysis and controlling for preintervention trends, we determined changes in rates of SMBG 2 years before and after the policy among 3219 continuously enrolled patients with diabetes receiving drug therapy within a multispecialty medical group (part of a health maintenance organization) serving approximately 300 000 patients. We also compared changes over time in regularity of medication use (mean days between dispensings) and mean HbA(1c) level among initiators and noninitiators of SMBG. RESULTS: The policy resulted in a small, significant increase in SMBG among insulin-treated patients (n = 1428). Among sulfonylurea-treated patients (n = 1791), the monthly initiation rate of SMBG increased by 14 new patients per 1000 (95% confidence interval [CI], 10 to 17), a doubling of the expected initiation rate. Test strip consumption increased during the first 6 months after the policy by 17.9 strips per cohort member (75% relative increase by 6 months; 95% CI, 50% to 101%). Compared with noninitiators of SMBG, initiators (n = 593) showed sudden, significant improvements in regularity of medication use by 6 months after initiation (-19.5 days between dispensings among those with low refill regularity [95% CI, -27.7 to -11.3]; -9.7 days among those with moderate regularity [95% CI, -12.3 to -7.1]), and in glucose control (-0.63% mean HbA(1c) level [as percentage of total hemoglobin] among those with poor baseline glycemic control [HbA(1c) >10%; 95% CI, -1.14% to -0.12%]). CONCLUSIONS: Providing free glucose monitors improved rates of self-monitoring in this health maintenance organization population, possibly by offering an initial incentive for patients to engage in more desirable patterns of care. Initiating SMBG was associated with increased regularity of medication use and a reduction in high blood glucose levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Abraira, C., Colwell, J. A., Nuttall, F. Q., Sawin, C. T., Nagel, N. J., Comstock, J. P., Emanuele, N. V., Levin, S. R., Henderson, W., Lee, H. S., et al. (1995) · Diabetes Care · doi:10.2337/diacare.18.8.1113 · Cited by 355
Cited by
Self-Monitoring of Blood Glucose in Patients With Type 2 Diabetes Who Are Not Using Insulin
Welschen, L. M. C., Bloemendal, E., Nijpels, G., Dekker, J. M., Heine, R. J., Stalman, W. A. B., & Bouter, L. M. (2005) · Diabetes Care · doi:10.2337/diacare.28.6.1510 · Cited by 374
Assessing Glycemia in Diabetes Using Self-monitoring Blood Glucose and Hemoglobin A 1c
Saudek, C. D., Derr, R. L., & Kalyani, R. R. (2006) · JAMA · doi:10.1001/jama.295.14.1688 · Cited by 373
Self-monitoring of blood glucose in patients with type 2 diabetes mellitus who are not using insulin
Malanda, U. L., Welschen, L. M., Riphagen, I. I., Dekker, J. M., Nijpels, G., & Bot, S. D. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005060.pub3 · Cited by 358
O’Kane, M. J., Bunting, B., Copeland, M., & Coates, V. E. (2008) · BMJ · doi:10.1136/bmj.39534.571644.be · Cited by 326
Martin, S., Schneider, B., Heinemann, L., Lodwig, V., Kurth, H.-J., Kolb, H., Scherbaum, W. A., & for the ROSSO Study Group (2006) · Diabetologia · doi:10.1007/s00125-005-0083-5 · Cited by 284
Metadata
- Authors
- Soumerai, S. B., Mah, C., Zhang, F., Adams, A., Barton, M., Fajtova, V., & Ross-Degnan, D.
- Venue
- Archives of Internal Medicine
- Publisher
- American Medical Association (AMA)
- Published
- 2004-03-22
- Volume
- 164
- Issue
- 6
- Pages
- 645
- ISSN
- 0003-9926 (ISSN-L)
- OpenAlex
- W2053651253
- Cited by
- 72
- References
- 1
- FWCI
- 5.53
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of Health Maintenance Organization Coverage of Self-monitoring Devices on Diabetes Self-care and Glycemic Control. https://app.cochat.ai/papers/10.1001/archinte.164.6.645
- The paper
- Soumerai, S. B., Mah, C., Zhang, F., Adams, A., Barton, M., Fajtova, V., & Ross-Degnan, D. (2004). Effects of Health Maintenance Organization Coverage of Self-monitoring Devices on Diabetes Self-care and Glycemic Control. Archives of Internal Medicine. https://doi.org/10.1001/archinte.164.6.645
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.