Enoxaparin Dosing and Associated Risk of In-Hospital Bleeding and Death in Patients With Non–ST-Segment Elevation Acute Coronary Syndromes
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The efficacy of enoxaparin sodium in non-ST-segment elevation acute coronary syndromes is well established; however, concerns remain regarding bleeding risk. The extent to which bleeding risk is attributable to excess dosing of enoxaparin is unclear. METHODS: Using data from the CRUSADE (Can Rapid Risk Stratification of Unstable Angina Patients Suppress Adverse Outcomes With Early Implementation of the ACC/AHA Guidelines) National Quality Improvement Initiative, we determined the frequency of administration of excess (>10 mg above the recommended dose), lower-than-recommended (>10 mg below the recommended dose), and recommended doses of enoxaparin. We also determined unadjusted and adjusted risks of in-hospital major bleeding and death associated with excess and lower-than-recommended doses of enoxaparin. RESULTS: Of 10 687 patients, 2002 (18.7%) received an excess dose and 3116 (29.2%) received a lower-than-recommended dose of enoxaparin. Patients receiving excess doses were older (median age, 78 vs 66 years), smaller (median body mass index [calculated as weight in kilograms divided by height in meters squared], 26.2 vs 27.8), and more likely to be female (59.5% vs 38.2%) than patients receiving recommended doses (P < .001 for all). After adjustment for baseline characteristics, an excess dose was significantly associated with major bleeding (odds ratio, 1.43; 95% confidence interval [CI], 1.18-1.75) and death (odds ratio, 1.35; 95% CI, 1.03-1.77) compared with a recommended dose. A lower-than-recommended dose was not associated with major bleeding (odds ratio, 1.01; 95% CI, 0.84-1.21), but there was a trend toward higher mortality (odds ratio, 1.25; 95% CI, 0.93-1.68). CONCLUSIONS: Almost half the patients treated with enoxaparin did not receive a recommended dose and had worse outcomes, especially those receiving an excess dose. Improved adherence to the recommended dose could substantially improve the safety profile of enoxaparin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comparison of Fondaparinux and Enoxaparin in Acute Coronary Syndromes
(2006) · New England Journal of Medicine · doi:10.1056/nejmoa055443 · Cited by 1,228 · cited 1×
“equal to or greater than that with either unfractionated heparin(3) or the newer selective Xa inhibitor fondaparinux.(4,6) Major bleeding rates with enoxaparin in clinical”
Cited by
2014 AHA/ACC Guideline for the Management of Patients With Non–ST-Elevation Acute Coronary Syndromes
Amsterdam, E. A., Wenger, N. K., Brindis, R. G., Casey, D. E., Ganiats, T. G., Holmes, D. R., Jaffe, A. S., Jneid, H., Kelly, R. F., Kontos, M. C., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.09.017 · Cited by 3,595
Self-citationAmsterdam, E. A., Wenger, N. K., Brindis, R. G., Casey, D. E., Ganiats, T. G., Holmes, D. R., Jaffe, A. S., Jneid, H., Kelly, R. F., Kontos, M. C., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000133 · Cited by 1,254
Amsterdam, E. A., Wenger, N. K., Brindis, R. G., Casey, D. E., Ganiats, T. G., Holmes, D. R., Jaffe, A. S., Jneid, H., Kelly, R. F., Kontos, M. C., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000134 · Cited by 1,059
Self-citationSubherwal, S., Bach, R. G., Chen, A. Y., Gage, B. F., Rao, S. V., Newby, L. K., Wang, T. Y., Gibler, W. B., Ohman, E. M., Roe, M. T., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.828541 · Cited by 1,011
Amsterdam, E. A., Wenger, N. K., Brindis, R. G., Casey, D. E., Ganiats, T. G., Holmes, D. R., Jaffe, A. S., Jneid, H., Kelly, R. F., Kontos, M. C., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.09.016 · Cited by 777
Metadata
- Authors
- LaPointe, N. M. A.
- Venue
- Archives of Internal Medicine
- Publisher
- American Medical Association (AMA)
- Published
- 2007-07-23
- Volume
- 167
- Issue
- 14
- Pages
- 1539
- ISSN
- 0003-9926 (ISSN-L)
- OpenAlex
- W2147101387
- Cited by
- 75
- References
- 1
- FWCI
- 7.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.