Standby Automatic Defibrillator: An Approach to Prevention of Sudden Coronary Death

Mirowski, M.·1970·Archives of Internal Medicine

Abstract

A laboratory model of an automatic standby defibrillator has been designed, developed, and tested successfully on dogs. Approximately 50 seconds after a sensor located in the right ventricle detects ventricular fibrillation, a discharge of the order of 30 to 50 wattseconds is delivered automatically to the heart through two electrodes, one which represents an integral part of the intracardiac sensing catheter, and the other positioned under the skin or on the surface of the anterior chest wall. In the event of successful defibrillation the device reverts to a standby condition. It is suggested that this device, when adapted for clinical use, might be implanted temporarily or permanently in selected patients particularly prone to develop ventricular fibrillation and thus provide them with some degree of protection from sudden coronary death.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archinte.1970.00310070160014

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 221

Metadata

Authors
Mirowski, M.
Venue
Archives of Internal Medicine
Published
1970-07-01
Volume
126
Issue
1
Pages
158
ISSN
0003-9926 (ISSN-L)
OpenAlex
W4242103444
Cited by
221
References
0
FWCI
1.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Standby Automatic Defibrillator: An Approach to Prevention of Sudden Coronary Death. https://app.cochat.ai/papers/10.1001/archinte.1970.00310070160014
The paper
Mirowski, M. (1970). Standby Automatic Defibrillator: An Approach to Prevention of Sudden Coronary Death. Archives of Internal Medicine. https://doi.org/10.1001/archinte.1970.00310070160014

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.