Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 360

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Inferior Vena Cava Filters: Indications, Safety, Effectiveness

Becker, Daniel M.·1992·Archives of Internal Medicine

Abstract

BACKGROUND: Preventing pulmonary embolization by interrupting vena caval flow has been attempted since 1893. Inferior vena cava (IVC) filters have been available for 20 years, and currently there are five filters commercially available in the United States (Greenfield filter, Titanium Greenfield filter, Simon-Nitinol filter, Bird's Nest filter, and LGM or Vena Tech filter) and two other filters under development (Amplatz filter and Günther filter). Although these devices are widely used, their clinical utility and safety have not been completely evaluated. Controlled clinical trials to determine the clinical role for IVC filters have not been attempted, but numerous case series describing the outcomes of the seven current filters have been published. We have systematically reviewed these studies to clarify what is known about the indications, safety, and effectiveness of IVC filters. METHODS: Using the MEDLINE database, all English-language publications since 1970 that included follow-up clinical information after filter insertion were reviewed and eight methodologic guidelines were employed to assess the scientific quality of the clinical information. RESULTS: Twenty-four case series were reviewed: 16 concerned the Greenfield filter (1632 patients), and eight dealt with newer designs (925 patients). Commonly noted methodologic problems included failure to report the initial extent of thromboembolic disease, incomplete description of the patient assembly process, and incomplete and potentially biased outcome assessment. Recurrent clinical pulmonary embolism was rare after filter placement, and only eight deaths from pulmonary embolism were reported. Filter complications were common but rarely life threatening; four (0.16%) deaths from filter complications were noted among the reviewed studies. Thrombotic complications following filter placement included insertion-site deep vein thrombosis and IVC obstruction. These events were rare, but they occurred with all filter types. CONCLUSIONS: Inferior vena cava filters appear to be effective in preventing recurrent pulmonary embolism. Despite the large published experience with IVC filters, many questions remain about their indications, safety, and effectiveness. Anticoagulant therapy, if not contraindicated, should be used in conjunction with filters. While there is no ideal filter, some situations call for specific filters. Filter selection and insertion require experience, modern angiographic technique, and collaboration between clinicians caring for patients and the interventional radiologists or surgeons inserting the device.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archinte.1992.00400220023005

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 360

Metadata

Authors
Becker, D. M.
Venue
Archives of Internal Medicine
Published
1992-10-01
Volume
152
Issue
10
Pages
1985
ISSN
0003-9926 (ISSN-L)
OpenAlex
W2072389928
Cited by
360
References
18
FWCI
9.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Inferior Vena Cava Filters: Indications, Safety, Effectiveness. https://app.cochat.ai/papers/10.1001/archinte.1992.00400220023005
The paper
Becker, D. M. (1992). Inferior Vena Cava Filters: Indications, Safety, Effectiveness. Archives of Internal Medicine. https://doi.org/10.1001/archinte.1992.00400220023005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.