The DOI matches its Crossref record.
Subcutaneous Low-Molecular-Weight Heparin Compared With Continuous IntravenoUnfractionated Unfractionated Heparin in the Treatment of Proximal Deep Vein Thrombosis
Abstract
BACKGROUND: A low-molecular-weight heparin, enoxaparin sodium, has been shown to be effective and safe in preventing deep vein thrombosis both in general surgery and in high-risk orthopedic surgery. We conducted a controlled, randomized trial with enoxaparin in the treatment of established deep vein thrombosis. METHODS: In a multicenter trial, we compared fixed-dose subcutaneous enoxaparin, given twice daily, with adjusted-dose intravenous unfractionated heparin (UFH) given by continuous intravenous infusion for the initial 10 days of treatment of patients with proximal vein thrombosis. The primary efficacy outcome was the change of the size of the thrombus assessed by repeated venograms between day 0 and day 10. The primary analysis of safety was based on the incidence of major bleeding during 10 days of treatment. RESULTS: There were 67 patients in each group. Venographic assessment of clot size evolution between day 0 and day 10 showed a statistically significant superiority (P < .002) of enoxaparin over the reference treatment with UFH. Moreover, the incidence of overall recurrent thromboembolic events during 10 days of treatment was significantly higher (P < .002) in the UFH group (seven of 67) than in the enoxaparin group (one of 67). There were no serious bleeding complications in either group. CONCLUSIONS: Enoxaparin is at least as effective and safe as UFH under the conditions of this study. Moreover, it is more comfortable for patients and less time-consuming for nurses and laboratories. Thus, our study confirmed, with the use of enoxaparin, other observations that low-molecular-weight heparin provides a real therapeutic advance in the treatment of deep vein thrombosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kearon (2012) · doi:10.1378/chest.11-2301 · Cited by 6,119
Antithrombotic Therapy for VTE Disease
Kearon, C., Akl, E. A., Ornelas, J., Blaivas, A., Jimenez, D., Bounameaux, H., Huisman, M., King, C. S., Morris, T. A., Sood, N., et al. (2016) · Chest · doi:10.1016/j.chest.2015.11.026 · Cited by 4,830
Prevention of Venous Thromboembolism
Geerts, W. H., Heit, J. A., Clagett, G. P., Pineo, G. F., Colwell, C. W., Anderson, F. A., & Wheeler, H. B. (2001) · Chest · doi:10.1378/chest.119.1_suppl.132s · Cited by 4,373
Warkentin, T. E., Levine, M. N., Hirsh, J., Horsewood, P., Roberts, R. S., Gent, M., & Kelton, J. G. (1995) · New England Journal of Medicine · doi:10.1056/nejm199505183322003 · Cited by 2,328
Antithrombotic Therapy for Venous Thromboembolic Disease
Hyers, T. M., Agnelli, G., Hull, R. D., Morris, T. A., Samama, M., Tapson, V., & Weg, J. G. (2001) · Chest · doi:10.1378/chest.119.1_suppl.176s · Cited by 2,042
Metadata
- Authors
- Simonneau, G.
- Venue
- Archives of Internal Medicine
- Publisher
- American Medical Association (AMA)
- Published
- 1993-07-12
- Volume
- 153
- Issue
- 13
- Pages
- 1541
- ISSN
- 0003-9926 (ISSN-L)
- OpenAlex
- W2118015645
- Cited by
- 232
- References
- 0
- FWCI
- 13.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Subcutaneous Low-Molecular-Weight Heparin Compared With Continuous IntravenoUnfractionated Unfractionated Heparin in the Treatment of Proximal Deep Vein Thrombosis. https://app.cochat.ai/papers/10.1001/archinte.1993.00410130045005
- The paper
- Simonneau, G. (1993). Subcutaneous Low-Molecular-Weight Heparin Compared With Continuous IntravenoUnfractionated Unfractionated Heparin in the Treatment of Proximal Deep Vein Thrombosis. Archives of Internal Medicine. https://doi.org/10.1001/archinte.1993.00410130045005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.