CoChat

Bronchodilator Delivery in Acute Airflow Obstruction: A Meta-analysis

Turner, Mark O. · 1997 · Archives of Internal Medicine
Cited by 133

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Objective: To compare the effect of bronchodilator delivery by use of a metered-dose inhaler (MDI) or wet nebulizer on objective measurements of acute airflow obstruction in adult patients. Methods: Published and unpublished research was identified by MEDLINE searches for articles published from 1966 to 1994, review of scientific citations, review of article bibliographies, communication with experts in the area of asthma therapy and aerosol delivery, primary investigators, and a manufacturer of spacer devices. Eighteen studies were selected from 159 potentially relevant articles by independent review in triplicate. Selection criteria included randomized trials that compared bronchodilator delivery by use of an MDI and wet nebulizer in adults with acute exacerbations of asthma or chronic obstructive pulmonary disease who were treated in an emergency department or a hospital. Data for patient characteristics, study setting, bronchodilator doses, outcomes, and methodological quality were independently extracted. Results: Twelve studies with a total of 507 patients had sufficient data to calculate an effect size (in SD units) for improvement in airflow obstruction after bronchodilator delivery. All but 2 studies used spacer devices with the MDI. The overall treatment effect size was -0.02 (95% confidence interval [CI], -0.20 to 0.16) that favored the MDI, but the magnitude of the effect size was not clinically or statistically significant. No significant effect was observed in the subgroup analyses that compared the diagnosis: asthma, -0.17 (CI, -0.41 to 0.07) compared with chronic obstructive pulmonary disease, 0.23 (CI, -0.35 to 0.81); bronchodilator dose; or methodological quality. The results of a sensitivity analysis that included 5 of 6 excluded studies supported the findings from the primary analysis: 0.05 (CI, -0.11 to 0.20). Conclusions: Bronchodilator delivery by means of an MDI or wet nebulizer is equivalent in the acute treatment of adults with airflow obstruction. Spacer devices were used for bronchodilator delivery with an MDI in most studies and are recommended for the treatment of acute airflow obstruction. The choice of the delivery method will depend on the need for expedient treatment, availability of staff, consideration of costs, and findings from studies designed to evaluate treatment effects from larger than standard doses of bronchodilators delivered by use of an MDI. Arch Intern Med. 1997;157:1736-1744

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archinte.1997.00440360162018

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 133

Metadata

Authors
Turner, M. O.
Venue
Archives of Internal Medicine
Published
1997-08-11
Volume
157
Issue
15
Pages
1736
ISSN
0003-9926 (ISSN-L)
OpenAlex
W2613729619
Cited by
133
References
2
FWCI
5.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bronchodilator Delivery in Acute Airflow Obstruction: A Meta-analysis. https://app.cochat.ai/papers/10.1001/archinte.1997.00440360162018
The paper
Turner, M. O. (1997). Bronchodilator Delivery in Acute Airflow Obstruction: A Meta-analysis. Archives of Internal Medicine. https://doi.org/10.1001/archinte.1997.00440360162018

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.