Genetic Heterogeneity of Dominant Optic Atrophy, Kjer Type: Identification of a Second Locus on Chromosome 18q12.2-12.3
Open accessThe DOI matches its Crossref record.
Abstract
OBJECTIVE: To evaluate a family with autosomal dominant optic atrophy, which has been previously linked to the Kidd blood group. DESIGN: Clinical evaluation with the assessment of visual acuity, color vision, and optic nerve appearance to determine affection status. Linkage analysis using polymorphic DNA markers. RESULTS: Visual acuities ranged from 20/20 to 6/200. Although linkage was excluded for chromosome 3q28-29, markers from chromosome 18 in the vicinity of the Kidd locus were linked to the disorder (D18S34 [maximal lod score (lodmax) of 5.38 at recombination fraction (theta) of 0.14], D18S548 [lod(max)=7.26, theta=0.09], D18S861 [lod(max)= 5.32, theta = 0.07], and D18S479 [lod(max) = 3.28, 0 = 0.12:]). Multipoint linkage analysis demonstrated lod scores of greater than 3 in an approximately 3-centimorgan region flanked by D18S34 and D18S479, using 98% penetrance and a phenocopy rate of 1/50. CONCLUSIONS: Dominant optic atrophy is genetically heterogeneous, with loci assigned to chromosomes 3q28-29 and 18q12.2-12.3. Dominant optic atrophy linked to 18q shows intrafamilial variation similar to that previously reported in families linked to 3q, with visual acuities ranging from normal to legal blindness. The overall distribution of visual acuities appears more favorable with the 18q phenotype. Both phenotypes appear to have a similar rate of visual decline.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Delettre, C., Lenaers, G., Griffoin, J.-M., Gigarel, N., Lorenzo, C., Belenguer, P., Pelloquin, L., Grosgeorge, J., Turc-Carel, C., Perret, E., et al. (2000) · Nature Genetics · doi:10.1038/79936 · Cited by 1,446
Alexander, C., Votruba, M., Pesch, U. E. A., Thiselton, D. L., Mayer, S., Moore, A., Rodriguez, M., Kellner, U., Leo-Kottler, B., Auburger, G., et al. (2000) · Nature Genetics · doi:10.1038/79944 · Cited by 1,330
Mitochondrial dysfunction as a cause of optic neuropathies
Carelli, V., Ross-Cisneros, F. N., & Sadun, A. A. (2004) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2003.10.003 · Cited by 839
Mitochondrial optic neuropathies—Disease mechanisms and therapeutic strategies
Yu-Wai-Man, P., Griffiths, P. G., & Chinnery, P. F. (2011) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2010.11.002 · Cited by 633
Systematic screen for human disease genes in yeast
Steinmetz, L. M., Scharfe, C., Deutschbauer, A. M., Mokranjac, D., Herman, Z. S., Jones, T., Chu, A. M., Giaever, G., Prokisch, H., Oefner, P. J., et al. (2002) · Nature Genetics · doi:10.1038/ng929 · Cited by 544
Metadata
- Authors
- Kerrison, J. B.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 1999-06-01
- Volume
- 117
- Issue
- 6
- Pages
- 805
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2162904421
- Cited by
- 113
- References
- 0
- FWCI
- 5.68
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Genetic Heterogeneity of Dominant Optic Atrophy, Kjer Type: Identification of a Second Locus on Chromosome 18q12.2-12.3. https://app.cochat.ai/papers/10.1001/archopht.117.6.805
- The paper
- Kerrison, J. B. (1999). Genetic Heterogeneity of Dominant Optic Atrophy, Kjer Type: Identification of a Second Locus on Chromosome 18q12.2-12.3. Archives of Ophthalmology. https://doi.org/10.1001/archopht.117.6.805
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.