Anatomical Outcomes of Surgery for Idiopathic Macular Hole as Determined by Optical Coherence Tomography
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: To determine the rate of anatomical closure of idiopathic macular holes undergoing vitreous surgery with respect to preoperative horizontal diameter as determined by optical coherence tomography (OCT) and to correlate postoperative visual acuity, duration of symptoms, and late reopening with initial idiopathic macular hole diameter by OCT. MATERIALS AND METHODS: Forty eyes of 40 patients with an idiopathic macular hole were examined with OCT before and after vitreous surgery. All eyes were treated with pars plana vitrectomy, peeling of posterior cortical vitreous, and dilute perfluoropropane or sulfur hexafluoride gas. Face-down positioning was maintained for 7 to 14 days. RESULTS: Twenty-two (92%) of 24 eyes with a preoperative idiopathic macular hole diameter smaller than 400 microm measured by OCT attained anatomical closure following surgery. Anatomical closure was observed in 9 (56%) of 16 eyes with a macular hole diameter of 400 microm or larger measured by OCT (P =.02). The median postoperative visual acuity improvement was 4 Snellen lines in the 31 eyes achieving anatomical closure and no change in the 9 eyes not achieving anatomical closure (P< .001). Late macular hole reopening at longer than 6 months occurred in 3 (10%) of 31 eyes with an initially closed macular hole. This event was observed only in macular holes 400 microm or larger measured by OCT. The preoperative macular hole diameter (P =.02) and duration of symptoms (P =.02) were factors predictive of anatomical closure of the macular hole postoperatively. CONCLUSIONS: The postoperative closure of idiopathic macular holes following vitreous surgery was related to the preoperative macular hole diameter determined by OCT, with lesions smaller than 400 microm demonstrating higher success rates. A trend toward greater visual acuity improvement was demonstrated for idiopathic macular holes smaller than 400 microm. Late reopening was only seen in macular holes that were 400 microm or larger measured by OCT. Preoperative analysis and measurement of idiopathic macular holes with OCT may help delineate postoperative expectations for successful anatomical closure of the macular hole, visual acuity, and long-term closure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Information Theory and an Extension of the Maximum Likelihood Principle
Akaike, H. (1998) · Springer Series in Statistics · doi:10.1007/978-1-4612-1694-0_15 · Cited by 17,781
Vitreous Surgery for Idiopathic Macular Holes: Results of a Pilot Study
Kelly, N. E. (1991) · Archives of Ophthalmology · doi:10.1001/archopht.1991.01080050068031 · Cited by 1,305
Imaging of Macular Diseases with Optical Coherence Tomography
Puliafito, C. A., Hee, M. R., Lin, C. P., Reichel, E., Schuman, J. S., Duker, J. S., Izatt, J. A., Swanson, E. A., & Fujimoto, J. G. (1995) · Ophthalmology · doi:10.1016/s0161-6420(95)31032-9 · Cited by 1,267
Idiopathic Senile Macular Hole: Its Early Stages and Pathogenesis
Gass, J. D. M. (1988) · Archives of Ophthalmology · doi:10.1001/archopht.1988.01060130683026 · Cited by 992
Optical Coherence Tomography of Macular Holes
Hee, M. R., Puliafito, C. A., Wong, C., Duker, J. S., Reichel, E., Schuman, J. S., Swanson, E. A., & Fujimoto, J. G. (1995) · Ophthalmology · doi:10.1016/s0161-6420(95)30959-1 · Cited by 503
Johnson, R. N., & Gass, J. D. M. (1988) · Ophthalmology · doi:10.1016/s0161-6420(88)33075-7 · Cited by 408
Gass, J. D. M. (1999) · Archives of Ophthalmology · doi:10.1001/archopht.117.6.821 · Cited by 342
Effect of autologous platelet concentrate in surgery for idiopathic macular hole
Paques, M., Chastang, C., Mathis, A., Sahel, J., Massin, P., Dosquet, C., Korobelnik, J.-F., Le Gargasson, J.-F., & Gaudric, A. (1999) · Ophthalmology · doi:10.1016/s0161-6420(99)00512-6 · Cited by 200
Late Re-opening of Macular Holes after Initially Successful Treatment with Vitreous Surgery
Duker, J. S., Wendel, R., Patel, A. C., & Puliafito, C. A. (1994) · Ophthalmology · doi:10.1016/s0161-6420(13)31174-9 · Cited by 105
Cited by
Duker, J. S., Kaiser, P. K., Binder, S., de Smet, M. D., Gaudric, A., Reichel, E., Sadda, S. R., Sebag, J., Spaide, R. F., & Stalmans, P. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2013.07.042 · Cited by 1,206
Recent developments in optical coherence tomography for imaging the retina
van Velthoven, M. E. J., Faber, D. J., Verbraak, F. D., van Leeuwen, T. G., & de Smet, M. D. (2007) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2006.10.002 · Cited by 343
Chen, T. C. (2005) · Archives of Ophthalmology · doi:10.1001/archopht.123.12.1715 · Cited by 327
Types of macular hole closure and their clinical implications
Kang, S. W. (2003) · British Journal of Ophthalmology · doi:10.1136/bjo.87.8.1015 · Cited by 290
Spiteri Cornish, K., Lois, N., Scott, N. W., Burr, J., Cook, J., Boachie, C., Tadayoni, R., la Cour, M., Christensen, U., & Kwok, A. K. H. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2013.10.020 · Cited by 198
“It was also noted that the rate of primary macular hole closure was higher in smaller holes, a finding confirmed in a case series of 40 patients.(24) Although smaller holes ( 400 mm) appear to close more successfully than larger holes (>400 mm), the evidence presented disclosed higher rates of primary and final macula…”
ResultKusuhara, S., Teraoka Escaño, M. F., Fujii, S., Nakanishi, Y., Tamura, Y., Nagai, A., Yamamoto, H., Tsukahara, Y., & Negi, A. (2004) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2004.04.063 · Cited by 196
Internal Limiting Membrane Removal during Macular Hole Surgery
Tognetto, D., Grandin, R., Sanguinetti, G., Minutola, D., Di Nicola, M., Di Mascio, R., & Ravalico, G. (2006) · Ophthalmology · doi:10.1016/j.ophtha.2006.02.061 · Cited by 172
Optical coherence tomography predictive factors for macular hole surgery outcome
Ruiz-Moreno, J. M., Staicu, C., Pinero, D. P., Montero, J., Lugo, F., & Amat, P. (2008) · British Journal of Ophthalmology · doi:10.1136/bjo.2007.136176 · Cited by 170
“Some authors have studied the possible correlation between preoperative OCT findings and anatomical”
BackgroundDAYANI, P. N., MALDONADO, R., FARSIU, S., & TOTH, C. A. (2009) · Retina · doi:10.1097/iae.0b013e3181b266bc · Cited by 160
Restored Photoreceptor Outer Segment and Visual Recovery After Macular Hole Closure
Sano, M., Shimoda, Y., Hashimoto, H., & Kishi, S. (2009) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2008.08.002 · Cited by 160
Optical Coherence Tomography Use in Evaluation of the Vitreoretinal Interface: A Review
Mirza, R. G., Johnson, M. W., & Jampol, L. M. (2007) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2007.04.007 · Cited by 158
Complications of vitreoretinal surgery
Belin, P. J., & Parke, D. W. (2020) · Current Opinion in Ophthalmology · doi:10.1097/icu.0000000000000652 · Cited by 44
Metadata
- Authors
- Ip, M. S.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2002-01-01
- Volume
- 120
- Issue
- 1
- Pages
- 29
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2002282409
- Cited by
- 381
- References
- 9
- FWCI
- 11.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.