A Population-Based Study of the Refractive Outcome in 10-Year-Old Preterm and Full-Term Children
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate the refractive outcome in 10-year-old prematurely born children and in full-term control children. METHODS: Retinoscopy during cycloplegia was performed in 213 prematurely born children from a previous population-based study on the incidence of retinopathy of prematurity and in 217 children born at term. The spherical equivalent, astigmatism, anisometropia, and significant refractive errors (defined as hypermetropia >3 diopters [D], myopia < or =-1 D, astigmatism > or =1 D in 1 or both eyes, and/or anisometropia > or =1 D) were analyzed. RESULTS: Significant refractive errors were found in 29.6% of the prematurely born and in 7.8% of the full-term children. Prematurely born children had higher prevalences of hypermetropia of more than 3 D, myopia of -1 D or less, astigmatism of 1 D or more, and anisometropia of 1 D or more than those born at term. In the preterm group, the cryotreated children had the greatest risk of refractive errors (16 [64%] of 25 children), with higher prevalences of myopia (<0, < or =-1, or <-3 D), astigmatism (> or =1 D), and anisometropia (> or =1 D). CONCLUSIONS: Significant refractive errors were 4 times more common in 10-year-old prematurely born children than in full-term controls. Cryotreated children had the highest risk, but prematurity per se was also associated with refractive errors. Ophthalmological follow-up of prematurely born children should, therefore, also include children without retinopathy of prematurity in the neonatal period.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Statistics for the Behavioral Sciences
Guitton, H., & Siegel, S. (1958) · Revue économique · doi:10.2307/3498751 · Cited by 35,245
Cognitive and Behavioral Outcomes of School-Aged Children Who Were Born Preterm: A Meta-analysis
Bhutta, A. T., Cleves, M. A., Casey, P. H., Cradock, M. M., & Anand, K. J. S. (2002) · JAMA · doi:10.1001/jama.288.6.728 · Cited by 2,392
(2003) · Archives of Ophthalmology · doi:10.1001/archopht.121.12.1769 · Cited by 1,001
Multiple Comparisons and Multiple Tests Using the SAS System
ROM, D. M., Tobias, R. D., & Wolfinger, R. D. (1999) · Cited by 436
(2001) · Archives of Ophthalmology · doi:10.1001/archopht.119.8.1110 · Cited by 364
NEW VISUAL ACUITY TEST FOR PRE‐SCHOOL CHILDREN
HYVÄRINEN, L., NÄSÄNEN, R., & LAURINEN, P. (1980) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.1980.tb08291.x · Cited by 288
O’Connor, A. R., Stephenson, T., Johnson, A., Tobin, M. J., Moseley, M. J., Ratib, S., Ng, Y., & Fielder, A. R. (2002) · Pediatrics · doi:10.1542/peds.109.1.12 · Cited by 283 · cited 4×
“A higher prevalence of myopia in prematurely born children without ROP than in those born at term has also been reported.(10,13,39) In the present study, prematurity per se seemed to have the greatest effect on myopia of less than −3 D, which could be due to a disturbance in ocular growth and refractive development, a…”
InfluentialStjernqvist, K., & SVENNINGSEN, N. W. (1999) · Acta Paediatrica · doi:10.1080/08035259950169594 · Cited by 251
Horwood, L. J., Mogridge, N., & Darlow, B. A. (1998) · Archives of Disease in Childhood - Fetal and Neonatal Edition · doi:10.1136/fn.79.1.f12 · Cited by 241
Jacobson, L. K., & Dutton, G. N. (2000) · Survey of Ophthalmology · doi:10.1016/s0039-6257(00)00134-x · Cited by 237
Cited by
Chen, J., & Smith, L. E. H. (2007) · Angiogenesis · doi:10.1007/s10456-007-9066-0 · Cited by 602
Development of human visual function
Braddick, O., & Atkinson, J. (2011) · Vision Research · doi:10.1016/j.visres.2011.02.018 · Cited by 403
Visual and visuocognitive development in children born very prematurely
Atkinson, J., & Braddick, O. (2007) · Progress in Brain Research · doi:10.1016/s0079-6123(07)64007-2 · Cited by 204
The relationship between anisometropia and amblyopia
Barrett, B. T., Bradley, A., & Candy, T. R. (2013) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2013.05.001 · Cited by 196
Ophthalmological problems associated with preterm birth
O'Connor, A. R., Wilson, C. M., & Fielder, A. R. (2007) · Eye · doi:10.1038/sj.eye.6702838 · Cited by 181
Metadata
- Authors
- Larsson, E. K.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2003-10-01
- Volume
- 121
- Issue
- 10
- Pages
- 1430
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2102378892
- Cited by
- 172
- References
- 29
- FWCI
- 5.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.