Comparison of the GDx VCC Scanning Laser Polarimeter, HRT II ConfocalScanning Laser Ophthalmoscope, and Stratus OCT Optical Coherence Tomographfor the Detection of Glaucoma

Medeiros, Felipe A.·2004·Archives of Ophthalmology

Abstract

OBJECTIVE: To compare the abilities of current commercially available versions of 3 optical imaging techniques: scanning laser polarimetry with variable corneal compensation (GDx VCC), confocal scanning laser ophthalmoscopy (HRT II [Heidelberg Retina Tomograph]), and optical coherence tomography (Stratus OCT) to discriminate between healthy eyes and eyes with glaucomatous visual field loss. METHODS: We included 107 patients with glaucomatous visual field loss and 76 healthy subjects of a similar age. All individuals underwent imaging with a GDx VCC, HRT II, and fast retinal nerve fiber layer scan with the Stratus OCT as well as visual field testing within a 6-month period. Receiver operating characteristic curves and sensitivities at fixed specificities (80% and 95%) were calculated for parameters reported as continuous variables. Diagnostic categorization (outside normal limits, borderline, or within normal limits) provided by each instrument after comparison with its respective normative database was also evaluated, and likelihood ratios were reported. Agreement on categorization between methods (weighted kappa) was assessed. RESULTS: After the exclusion of subjects with unacceptable images, the final study sample included 141 eyes of 141 subjects (75 with glaucoma and 66 healthy control subjects). Mean +/- SD mean deviation of the visual field test result for patients with glaucoma was -4.87 +/- 3.9 dB, and 70% of these patients had early glaucomatous visual field damage. No statistically significant difference was found between the areas under the receiver operating characteristic curves (AUCs) for the best parameters from the GDx VCC (nerve fiber indicator, AUC = 0.91), Stratus OCT (retinal nerve fiber layer inferior thickness, AUC = 0.92), and HRT II (linear discriminant function, AUC = 0.86). Abnormal results for each of the instruments, after comparison with their normative databases, were associated with strong positive likelihood ratios. Chance-corrected agreement (weighted kappa) among the 3 instruments ranged from moderate to substantial (0.50-0.72). CONCLUSIONS: The AUCs and the sensitivities at high specificities were similar among the best parameters from each instrument. Abnormal results (as compared with each instrument's normative database) were associated with high likelihood ratios and large effects on posttest probabilities of having glaucomatous visual field loss. Calculation of likelihood ratios may provide additional information to assist the clinician in diagnosing glaucoma with these instruments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archopht.122.6.827

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 455

Metadata

Authors
Medeiros, F. A.
Venue
Archives of Ophthalmology
Published
2004-06-01
Volume
122
Issue
6
Pages
827
ISSN
0003-9950 (ISSN-L)
OpenAlex
W2126692927
Cited by
455
References
5
FWCI
43.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of the GDx VCC Scanning Laser Polarimeter, HRT II ConfocalScanning Laser Ophthalmoscope, and Stratus OCT Optical Coherence Tomographfor the Detection of Glaucoma. https://app.cochat.ai/papers/10.1001/archopht.122.6.827
The paper
Medeiros, F. A. (2004). Comparison of the GDx VCC Scanning Laser Polarimeter, HRT II ConfocalScanning Laser Ophthalmoscope, and Stratus OCT Optical Coherence Tomographfor the Detection of Glaucoma. Archives of Ophthalmology. https://doi.org/10.1001/archopht.122.6.827

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.