Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 184

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Visual Field Abnormalities in Nonarteritic Anterior Ischemic Optic Neuropathy: Their Pattern and Prevalence at Initial Examination

Hayreh, Sohan Singh · 2005 · Archives of Ophthalmology

Abstract

OBJECTIVE: To evaluate the pattern of various types of visual field defects and their prevalence at initial examination of nonarteritic anterior ischemic optic neuropathy (NA-AION). METHODS: The data were compiled from 312 consecutive eyes (in 265 patients) that fulfilled our inclusion and exclusion criteria. A comprehensive ophthalmic evaluation was performed, including recording of visual acuity, visual fields with a Goldmann perimeter (using I-2e, I-4e, and V-4e targets regularly), and intraocular pressure; slitlamp examination of the anterior segment; ophthalmoscopy; color fundus photography; and in acute cases, fluorescein fundus angiography. The visual field defects were divided into 2 groups: (1) general field defects and (2) various types of scotoma in the central 30 degrees . The prevalence of various types of visual field defects was estimated for I-2e, I-4e, and V-4e isopters by dividing the total number of eyes with the defect by the total number of eyes that could see that particular target. Exact 95% confidence limits for the prevalence were computed. RESULTS: Of the 265 patients, 169 (63.7%) were male and the mean +/- SD patient age was 55.0 +/- 9.1 years. The median interval between the first visual field test and the onset of NA-AION was 2 weeks. Of the 312 eyes, the I-2e target was seen by 75.3%, the I-4e target by 90.7%, and the V-4e target by 100%. Overall prevalence of general visual field defects was 83.4% with I-2e, 78.8% with I-4e, and 68.9% with V-4e, whereas the prevalence of scotoma(s) within the central 30 degrees was 55.3%, 49.5%, and 36.2%, respectively. Central scotoma was seen in 48.5% with I-2e, 43.8% with I-4e, and 29.2% with V-4e. A detailed prevalence of various types of visual field defects is given. Relative inferior altitudinal defect was most common (34.9% with I-2e and 22.3% with I-4e), but the absolute inferior altitudinal defect was seen in only 8.0%. By contrast, absolute inferior nasal sector visual loss was the most common defect detected in NA-AION (22.4%), but it occurred in only 3.4% with I-2e and 11.0% with I-4e. Overall, loss of the nasal part of the visual field was the most common occurrence. CONCLUSIONS: Our study demonstrated that NA-AION eyes may initially show a variety of optic nerve-related visual field defects. Our study also showed that an absolute inferior nasal visual field defect is much more common (22.4%) than an absolute inferior altitudinal visual field defect (8.0%) in NA-AION and could be considered the most characteristic single field defect in NA-AION. We found that a combination of relative inferior altitudinal defect with absolute inferior nasal defect is usually the most common pattern in NA-AION.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archopht.123.11.1554

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 184

Metadata

Authors
Hayreh, S. S.
Venue
Archives of Ophthalmology
Published
2005-11-01
Volume
123
Issue
11
Pages
1554
ISSN
0003-9950 (ISSN-L)
OpenAlex
W2036928561
Cited by
184
References
1
FWCI
5.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Visual Field Abnormalities in Nonarteritic Anterior Ischemic Optic Neuropathy: Their Pattern and Prevalence at Initial Examination. https://app.cochat.ai/papers/10.1001/archopht.123.11.1554
The paper
Hayreh, S. S. (2005). Visual Field Abnormalities in Nonarteritic Anterior Ischemic Optic Neuropathy: Their Pattern and Prevalence at Initial Examination. Archives of Ophthalmology. https://doi.org/10.1001/archopht.123.11.1554

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.