High-Speed Ultra–High-Resolution Optical Coherence Tomography Findings in Hydroxychloroquine Retinopathy
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: To compare structural changes in the retina seen on high-speed ultra-high-resolution optical coherence tomography (hsUHR-OCT) with multifocal electroretinography (mfERG) and automated visual fields in patients receiving hydroxychloroquine. METHODS: Fifteen patients receiving hydroxychloroquine were evaluated clinically with hsUHR-OCT, mfERG, and automated visual fields. Six age-matched subjects were imaged with hsUHR-OCT and served as controls. RESULTS: Distinctive discontinuity of the perifoveal photoreceptor inner segment/outer segment junction and thinning of the outer nuclear layer were seen with hsUHR-OCT in patients with mild retinal toxic effects. Progression to complete loss of the inner segment/outer segment junction and hyperscattering at the outer segment level were seen in more advanced cases. The mfERG abnormalities correlated with the hsUHR-OCT findings. Asymptomatic patients had normal hsUHR-OCT and mfERG results. CONCLUSION: Distinctive abnormalities in the perifoveal photoreceptor inner segment/outer segment junction were seen on hsUHR-OCT in patients receiving hydroxychloroquine who also were symptomatic and had abnormalities on automated visual fields and mfERG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultrahigh-resolution ophthalmic optical coherence tomography
Drexler, W., Morgner, U., Ghanta, R. K., Kärtner, F. X., Schuman, J. S., & Fujimoto, J. G. (2001) · Nature Medicine · doi:10.1038/86589 · Cited by 962
Self-citation
Cited by
Revised Recommendations on Screening for Chloroquine and Hydroxychloroquine Retinopathy
Marmor, M. F., Kellner, U., Lai, T. Y. Y., Lyons, J. S., & Mieler, W. F. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2010.11.017 · Cited by 710
Hydroxychloroquine retinopathy
Yusuf, I. H., Sharma, S., Luqmani, R., & Downes, S. M. (2017) · Eye · doi:10.1038/eye.2016.298 · Cited by 271
Michaelides, M. (2011) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2010.321 · Cited by 201
Comparison of Screening Procedures in Hydroxychloroquine Toxicity
Marmor, M. F. (2012) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2011.371 · Cited by 196
Hydroxychloroquine-related retinal toxicity
Ding, H. J., Denniston, A. K., Rao, V. K., & Gordon, C. (2016) · Rheumatology · doi:10.1093/rheumatology/kev357 · Cited by 100
Metadata
- Authors
- Rodriguez-Padilla, J. A.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2007-06-01
- Volume
- 125
- Issue
- 6
- Pages
- 775
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2100667055
- Cited by
- 151
- References
- 1
- FWCI
- 8.08
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.