Normal Variability of Static Perimetric Threshold Values Across the Central Visual Field
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
We assessed the variability of results in normal subjects of computerized static threshold perimetry of the central 30 degrees field. Variability of measured threshold values was highly dependent on eccentricity. This included variability among individuals, test-to-test variability within individuals, and intratest variability. All values were significantly larger in the midperiphery than centrally. We found that the mean sensitivity decrement with age was eccentricity dependent, so that the age-corrected normal visual field became not only depressed but also steeper with age. Distributions of individual pointwise deviations from the age-corrected normal mean thresholds were significantly nongaussian. The dependency of variability on test point location, the nongaussian distributions of deviations from age-corrected means, and the variability of age-induced sensitivity reduction should all be considered in the interpretation of computerized visual fields, and particularly in the design of statistical programs for field analysis. Programs not considering these factors are likely to result in misleading analyses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2005) · Technometrics · doi:10.1198/tech.2005.s303 · Cited by 17,923
Multivariate Statistical Methods
(2008) · Encyclopedia of Public Health · doi:10.1007/978-1-4020-5614-7_2263 · Cited by 5,580
Influence of Age on the Visual Fields of Normal Subjects
Haas, A., Flammer, J., & Schneider, U. (1986) · American Journal of Ophthalmology · doi:10.1016/0002-9394(86)90595-7 · Cited by 165
Age-Related Changes of the Normal Visual Field
Jaffe, G. J., Alvarado, J. A., & Juster, R. P. (1986) · Archives of Ophthalmology · doi:10.1001/archopht.1986.01050190079043 · Cited by 135
The Normal Visual Field on the Humphrey Field Analyzer
Brenton, R. S., & Phelps, C. D. (1986) · Ophthalmologica · doi:10.1159/000309679 · Cited by 118
Drance, S. M., Berry, V., & Hughes, A. (1967) · American Journal of Ophthalmology · doi:10.1016/0002-9394(67)93644-6 · Cited by 83
Cited by
Retinal Ganglion Cell Atrophy Correlated With Automated Perimetry in Human Eyes With Glaucoma
Quigley, H. A., Dunkelberger, G. R., & Green, W. R. (1989) · American Journal of Ophthalmology · doi:10.1016/0002-9394(89)90488-1 · Cited by 1,123
A new generation of algorithms for computerized threshold perimetry, SITA
Bengtsson, B., Olsson, J., Heijl, A., & Rootzén, H. (1997) · Acta Ophthalmologica Scandinavica · doi:10.1111/j.1600-0420.1997.tb00392.x · Cited by 431
Self-citationLinking structure and function in glaucoma
Harwerth, R. S., Wheat, J. L., Fredette, M. J., & Anderson, D. R. (2010) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2010.02.001 · Cited by 293
The incidence of irreversible retinal toxicity in patients treated with hydroxychloroquine
Mavrikakis, I., Sfikakis, P. P., Mavrikakis, E., Rougas, K., Nikolaou, A., Kostopoulos, C., & Mavrikakis, M. (2003) · Ophthalmology · doi:10.1016/s0161-6420(03)00409-3 · Cited by 256
Multifocal VEP and ganglion cell damage: applications and limitations for the study of glaucoma
Hood, D. (2003) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(02)00061-7 · Cited by 245
“It may reflect the small nasotemporal difference in sensitivity (approximately 1 dB or less) that has been reported for visual field measurements (Brenton and Phelps, 1986; Heijl et al., 1987).”
Background
Metadata
- Authors
- Heijl, A., Lindgren, G., & Olsson, J.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 1987-11-01
- Volume
- 105
- Issue
- 11
- Pages
- 1544-1549
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2065289190
- Cited by
- 442
- References
- 6
- FWCI
- 11.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.