The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Reproducibility and Responsiveness of the VF-14: An Index of Functional Impairment in Patients With Cataracts
Abstract
OBJECTIVES: To assess the test-retest reliability and responsiveness of the VF-14, which is an index of functional impairment in patient with cataracts. DESIGN: Observational longitudinal study. Patients were enrolled prior to undergoing their first cataract surgery between July 15 and December 15, 1991, and they were followed up for 1 year after surgery. SETTING: Patients were recruited from 72 ophthalmologists' practices in three US cities. PATIENTS: Five hundred fifty-two patients who had undergone a surgical procedure in only one eye by the 4-month postoperative follow-up (responsiveness analyses) and a subset of these (n = 426) who had not subsequently undergone surgery for the second eye by the 12-month postoperative follow-up (reproducibility analyses). MAIN OUTCOME MEASURES: Two health status measures (the VF-14 and the Sickness Impact Profile, two global measures of a patient's trouble and satisfaction with his or her vision, and best corrected visual acuity in each eye. RESULTS: The VF-14 is highly reproducible, with an intraclass correlation coefficient of .79 when patient-rated criteria are used to define stable patients. The intraclass correlation coefficient was lower (.57 to .71) when various measures of visual acuity were used to define stable patients. The VF-14 is also about three times more responsive to a change in vision than the Sickness Impact Profile, which is a generic health status measure (effect size of approximately 1.00 vs 0.30). Estimates of the responsiveness of the VF-14 and the Sickness Impact Profile were not associated with preoperative visual acuity in the operated on or better eye. Responsiveness of the VF-14, however, was higher in patients with greater self-rated trouble with vision preoperatively. CONCLUSIONS: The VF-14 was reproducible in stable patients during an 8-month period, and it was more responsive to clinically significant changes in vision than was a generic health status measure (ie, the Sickness Impact Profile).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect Sizes for Interpreting Changes in Health Status
Kazis, L. E., Anderson, J. J., & Meenan, R. F. (1989) · Medical Care · doi:10.1097/00005650-198903001-00015 · Cited by 2,401
Responsiveness and validity in health status measurement: a clarification
Guyatt, G. H., Deyo, R. A., Charlson, M., Levine, M. N., & Mitchell, A. (1989) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(89)90128-5 · Cited by 480
Cited by
Asbell, P. A., Dualan, I., Mindel, J. S., Brocks, D., Ahmad, M., & Epstein, S. P. (2005) · The Lancet · doi:10.1016/s0140-6736(05)17911-2 · Cited by 659
Bonomi, A. E., Patrick, D. L., Bushnell, D. M., & Martin, M. (2000) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(99)00123-7 · Cited by 558
Middel, B., & Van Sonderen, E. (2002) · International Journal of Integrated Care · doi:10.5334/ijic.65 · Cited by 464
Visual Function and Quality of Life Among Patients With Glaucoma
Parrish, R. K. (1997) · Archives of Ophthalmology · doi:10.1001/archopht.1997.01100160617016 · Cited by 396
Terwee, C. B., Gerding, M. N., Dekker, F. W., Prummel, M. F., & Wiersinga, W. M. (1998) · British Journal of Ophthalmology · doi:10.1136/bjo.82.7.773 · Cited by 321
Metadata
- Authors
- Cassard, S. D.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 1995-12-01
- Volume
- 113
- Issue
- 12
- Pages
- 1508
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2063327528
- Cited by
- 167
- References
- 2
- FWCI
- 8.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reproducibility and Responsiveness of the VF-14: An Index of Functional Impairment in Patients With Cataracts. https://app.cochat.ai/papers/10.1001/archopht.1995.01100120038005
- The paper
- Cassard, S. D. (1995). Reproducibility and Responsiveness of the VF-14: An Index of Functional Impairment in Patients With Cataracts. Archives of Ophthalmology. https://doi.org/10.1001/archopht.1995.01100120038005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.