The DOI matches its Crossref record.
An Objective Evaluation of Eyedrop Instillation in Patients With Glaucoma
Abstract
OBJECTIVES: To evaluate the performance of patients with ocular hypertension and glaucoma who are experienced in the instillation of topical ocular hypotensive medications. METHODS: We conducted a prospective, open-label study at a single private practice site. We enrolled 139 patients with a diagnosis of glaucoma or ocular hypertension who used 1 or more topical ocular hypotensive medications for at least 6 months and who instilled their own medications. Patients were questioned regarding their use of topical ocular hypotensive medications, and we used a video recording to evaluate patient performance of eyedrop instillation with 2 bottle designs. RESULTS: Patients reported relatively good performance on eyedrop instillation. One hundred twenty-nine of 139 patients (92.8%) reported no problem putting in their eyedrops, and 86 of 139 (61.9%) believed that they never missed their eye when administering the drops. The proportions of patients who were able to instill a single drop into the eye without touching the bottle to the eye were 14 of 64 (21.9%) with a 15-mL bottle and 36 of 117 (30.8%) with a 2.5-mL bottle. CONCLUSIONS: Under a single direct observation, patients experienced in the use of topical ocular hypotensive agents performed relatively poorly when instilling a single eyedrop into the eye without touching the bottle tip to the eye or the ocular adnexae. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00522600.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Primary Open-Angle Glaucoma Preferred Practice Pattern®
Gedde, S. J., Vinod, K., Wright, M. M., Muir, K. W., Lind, J. T., Chen, P. P., Li, T., & Mansberger, S. L. (2021) · Ophthalmology · doi:10.1016/j.ophtha.2020.10.022 · Cited by 474
Sleath, B., Blalock, S., Covert, D., Stone, J. L., Skinner, A. C., Muir, K., & Robin, A. L. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2011.05.013 · Cited by 366
Self-citationCraven, R. E., Katz, J. L., Wells, J. M., & Giamporcaro, J. E. (2012) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2012.03.025 · Cited by 344
A review on therapeutic contact lenses for ocular drug delivery
Maulvi, F. A., Soni, T. G., & Shah, D. O. (2016) · Drug Delivery · doi:10.3109/10717544.2016.1138342 · Cited by 270
Serle, J. B., Katz, L. J., McLaurin, E., Heah, T., Ramirez-Davis, N., Usner, D. W., Novack, G. D., & Kopczynski, C. C. (2018) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2017.11.019 · Cited by 269
Metadata
- Authors
- Stone, J. L.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2009-06-08
- Volume
- 127
- Issue
- 6
- Pages
- 732
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W1976180471
- Cited by
- 230
- References
- 0
- FWCI
- 6.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Objective Evaluation of Eyedrop Instillation in Patients With Glaucoma. https://app.cochat.ai/papers/10.1001/archophthalmol.2009.96
- The paper
- Stone, J. L. (2009). An Objective Evaluation of Eyedrop Instillation in Patients With Glaucoma. Archives of Ophthalmology. https://doi.org/10.1001/archophthalmol.2009.96
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.