Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 220

The DOI matches its Crossref record.

Interrater Reliability of Drug-Induced Sleep Endoscopy

Kezirian, Eric J., White, David P., Malhotra, Atul, Ma, Wendy, McCulloch, Charles E., Goldberg, Andrew N. · 2010 · Archives of Otolaryngology–Head & Neck Surgery

Abstract

OBJECTIVE: To determine the interrater reliability of drug-induced sleep endoscopy (DISE). DESIGN: Prospective cohort; blinded comparison. SETTING: Academic referral center. PARTICIPANTS: Subjects with obstructive sleep apnea unable to tolerate positive airway pressure therapy. INTERVENTIONS: Drug-induced sleep endoscopy was performed with intravenous propofol infusion to achieve sedation, and the videoendoscopy recording was evaluated by 2 independent reviewers. MAIN OUTCOME MEASURES: The following outcomes were measured: a global assessment of obstruction at the palate and/or hypopharynx; the degree of obstruction at the palate and hypopharynx; and the contribution of individual structures (palate, tonsils, tongue, epiglottis, and lateral pharyngeal walls) to obstruction. RESULTS: A total of 108 subjects underwent DISE examination. Diagnostic sleep studies demonstrated a mean (SD) apnea-hypopnea index of 39.6 (24.0). Three-quarters of the subjects demonstrated multilevel airway obstruction at the palate and hypopharynx, with a diversity of individual structures contributing to obstruction. The interrater reliability for the presence of obstruction at the palate and hypopharynx (kappa values, 0.76 and 0.79, respectively) was higher than for the degree of obstruction (weighted kappa values, 0.60 and 0.44). The interrater reliability for the assessment of primary structures contributing to obstruction at the palate and hypopharynx (0.70 and 0.86) was higher than for the contributions of individual structures (kappa values, 0.42-0.71). The interrater reliability for evaluation of the hypopharyngeal structures was higher than for those of the palate region. CONCLUSION: The interrater reliability of DISE is moderate to substantial. Trial Registration clinicaltrials.gov Identifier: NCT00695214.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archoto.2010.26

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 220

Metadata

Authors
Kezirian, E. J., White, D. P., Malhotra, A., Ma, W., McCulloch, C. E., & Goldberg, A. N.
Venue
Archives of Otolaryngology–Head & Neck Surgery
Published
2010-04-19
Volume
136
Issue
4
Pages
393
ISSN
0886-4470 (ISSN-L)
OpenAlex
W2107168729
Cited by
220
References
0
FWCI
10.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Interrater Reliability of Drug-Induced Sleep Endoscopy. https://app.cochat.ai/papers/10.1001/archoto.2010.26
The paper
Kezirian, E. J., White, D. P., Malhotra, A., Ma, W., McCulloch, C. E., & Goldberg, A. N. (2010). Interrater Reliability of Drug-Induced Sleep Endoscopy. Archives of Otolaryngology–Head & Neck Surgery. https://doi.org/10.1001/archoto.2010.26

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.