Clinical Experience With Impedance Audiometry
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Impedance audiometry was performed as part of the routine clinical examination in a consecutive series of more than 400 patients with various types and degrees of hearing impairment. An electroacoustic bridge (Madsen, ZO 70) was used to carry out the measurement of tympanometry, acoustic impedance, and threshold for the acoustic reflex. Results indicate that, while individual components of the total impedance battery lack diagnostic precision, the overall pattern of results yielded by the complete battery can be of great diagnostic value, especially in the evaluation of young children.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Most ears tested with the static tympanometry test displayed results suggestive of a normal mobility of the tympano-ossicular chain (type A tympanogram) (Jerger 1970).”
From Exploring the middle ear function in patients with a cluster of symptoms including tinnitus, hyperacusis, ear fullness and/or pain (2022) · cites this paper as Jerger 1970
Citations
Cites
THRESHOLD OF REFLEX CONTRACTIONS OF MUSCLES OF MIDDLE EAR AND RECRUITMENT OF LOUDNESS
METZ, O. (1952) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.1952.00710010550003 · Cited by 212
Klockhoff, I. (1961) · PubMed · Cited by 154
The Use of the Electro-Acoustic Impedance Bridge in the Assessment of Middle Ear Function
Brooks, D. N. (1969) · International Audiology · doi:10.3109/05384916909070226 · Cited by 147
The scope and application of current audiometric tests
Lidén, G. (1969) · The Journal of Laryngology & Otology · doi:10.1017/s0022215100070651 · Cited by 143
An Electroacoustic Impedance Measuring Bridge for Clinical Use
Terkildsen, K., & Nielsen, S. S. (1960) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.1960.00740010347009 · Cited by 137
An Objective Method of Detecting Fluid in the Middle Ear
Brooks, D. N. (1968) · International Audiology · doi:10.3109/05384916809074333 · Cited by 114
Improved Technique for Detailed Measurements of the Middle Ear Impedance
Møller, A. R. (1960) · The Journal of the Acoustical Society of America · doi:10.1121/1.1908029 · Cited by 87
XLVI Acoustic Measurement of the Middle Ear Function
Zwislocki, J. J. (1961) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348946107000222 · Cited by 56
Acoustic impedance of pathological ears.
Zwislocki, J. J., & Feldman, A. S. (1970) · PubMed · Cited by 51
Impedance Measurements at the Eardrum as an Aid to Diagnosis
Feldman, A. S. (1963) · Journal of Speech and Hearing Research · doi:10.1044/jshr.0604.315 · Cited by 45
Cited by
Bess, F. H., Dodd-Murphy, J., & Parker, R. A. (1998) · Ear and Hearing · doi:10.1097/00003446-199810000-00001 · Cited by 847
Studies in Impedance Audiometry: I. Normal and Sensorineural Ears
Jerger, J., Jerger, S., & Mauldin, L. (1972) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.1972.00770090791004 · Cited by 328
Self-citationComorbidity of Auditory Processing, Language, and Reading Disorders
Sharma, M., Purdy, S. C., & Kelly, A. S. (2009) · Journal of Speech, Language, and Hearing Research · doi:10.1044/1092-4388(2008/07-0226 · Cited by 318
Distortion Product Emissions in Humans: I. Basic Properties in Normally Hearing Subjects
Lonsbury‐Martin, B. L., Harris, F. P., Hawkins, M. D., Stagner, B. B., & Martin, G. K. (1990) · Annals of Otology Rhinology & Laryngology · doi:10.1177/00034894900990s501 · Cited by 267
Damoiseaux, R. A. M. J. (2000) · BMJ · doi:10.1136/bmj.320.7231.350 · Cited by 236
Metadata
- Authors
- Jerger, J.
- Venue
- Archives of Otolaryngology - Head and Neck Surgery
- Publisher
- American Medical Association (AMA)
- Published
- 1970-10-01
- Volume
- 92
- Issue
- 4
- Pages
- 311-324
- ISSN
- 0886-4470 (ISSN-L)
- OpenAlex
- W2027650661
- Cited by
- 1,768
- References
- 17
- FWCI
- 35.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.