The DOI matches its Crossref record.
Facial Skeletal Augmentation Using Hydroxyapatite Cement
Abstract
This study investigates the use of a new calcium phosphate cement, which sets to solid, microporous hydroxyapatite, for facial bone augmentation. In six dogs, the supraorbital ridges were augmented bilaterally with this hydroxyapatite cement. On one side, the hydroxyapatite cement was placed directly onto the bone within a subperiosteal pocket. On the opposite side, the cement was contained within a collagen membrane tubule and then inserted into a subperiosteal pocket. The use of collagen tubules facilitated easy, precise placement of the cement. All implants maintained their original augmented height throughout the duration of the study. They were well tolerated without extrusion or migration, and there was no significant sustained inflammatory response. Histologic studies, performed at 3, 6, and 9 months revealed that when the cement was placed directly onto bone, progressive replacement of the implant by bone (osseointegration of the hydroxyapatite with the underlying bone) without a loss of volume was observed. In contrast, when the cement-collagen tubule combination was inserted, primarily a fibrous union was noted. Despite such fibrous union, the hydroxyapatite-collagen implant solidly bonded to the underlying bone, and no implant resorption was observed. Hydroxyapatite cement can be used successfully for the experimental augmentation of the craniofacial skeleton and may be applicable for such uses in humans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Calcium Phosphate Cement: Review of Mechanical and Biological Properties
Ambard, A. J., & Mueninghoff, L. (2006) · Journal of Prosthodontics · doi:10.1111/j.1532-849x.2006.00129.x · Cited by 407
Calcium orthophosphate cements for biomedical application
Dorozhkin, S. V. (2008) · Journal of Materials Science · doi:10.1007/s10853-008-2527-z · Cited by 334
Zhao, L., Weir, M. D., & Xu, H. H. K. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.05.017 · Cited by 334
REPAIR OF CRANIOTOMY DEFECTS USING BONE MARROW STROMAL CELLS
Krebsbach, P. H., Mankani, M. H., Satomura, K., Kuznetsov, S. A., & Robey, P. G. (1998) · Transplantation · doi:10.1097/00007890-199811270-00002 · Cited by 279
Review: Bone tissue engineering: The role of interstitial fluid flow
Hillsley, M. V., & Frangos, J. A. (1994) · Biotechnology and Bioengineering · doi:10.1002/bit.260430706 · Cited by 270
Metadata
- Authors
- Shindo, M. L., Costantino, P. D., Friedman, C. D., & Chow, L. C.
- Venue
- Archives of Otolaryngology - Head and Neck Surgery
- Publisher
- American Medical Association (AMA)
- Published
- 1993-02-01
- Volume
- 119
- Issue
- 2
- Pages
- 185-190
- ISSN
- 0886-4470 (ISSN-L)
- OpenAlex
- W1990429008
- Cited by
- 175
- References
- 0
- FWCI
- 2.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Facial Skeletal Augmentation Using Hydroxyapatite Cement. https://app.cochat.ai/papers/10.1001/archotol.1993.01880140069012
- The paper
- Shindo, M. L., Costantino, P. D., Friedman, C. D., & Chow, L. C. (1993). Facial Skeletal Augmentation Using Hydroxyapatite Cement. Archives of Otolaryngology - Head and Neck Surgery. https://doi.org/10.1001/archotol.1993.01880140069012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.