Plasma Cortisol Determination for the Dexamethasone Suppression Test: Comparison of Competitive Protein-Binding and Commercial Radioimmunoassay Methods

Ritchie, James C. · 1985 · Archives of General Psychiatry
Cited by 40

The DOI matches its Crossref record.

Abstract

Quality control serum samples and postdexamethasone plasma pools were used to compare 16 commercial cortisol radioimmunoassay kits with the competitive protein-binding assay for plasma glucocorticoids that we used to standardize the dexamethasone suppression test (DST). Thirteen radioimmunoassays gave higher criterion values for the DST than those established using the competitive protein-binding assay. The range of radioimmunoassay criterion values was 4.34 to 8.70 mu mg/dL. Possible explanations are given for these findings, and their importance to the clinical utility of the DST are emphasized. Each laboratory should validate its own criterion cortisol value for depression based on local data, including appropriate control groups.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archpsyc.1985.01790280075007

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 40

Metadata

Authors
Ritchie, J. C.
Venue
Archives of General Psychiatry
Published
1985-05-01
Volume
42
Issue
5
Pages
493
ISSN
0003-990X (ISSN-L)
OpenAlex
W1994778023
Cited by
40
References
0
FWCI
2.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Plasma Cortisol Determination for the Dexamethasone Suppression Test: Comparison of Competitive Protein-Binding and Commercial Radioimmunoassay Methods. https://app.cochat.ai/papers/10.1001/archpsyc.1985.01790280075007
The paper
Ritchie, J. C. (1985). Plasma Cortisol Determination for the Dexamethasone Suppression Test: Comparison of Competitive Protein-Binding and Commercial Radioimmunoassay Methods. Archives of General Psychiatry. https://doi.org/10.1001/archpsyc.1985.01790280075007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.