CoChat

Liver Transplantation in Rats Using Small-for-Size Grafts: A Study of Hemodynamic and Morphological Changes

Open access
Man, Kwan · 2001 · Archives of Surgery
Cited by 188

The DOI matches its Crossref record.

Abstract

BACKGROUND: Damage to a small-for-size liver graft after reperfusion is frequently observed but the mechanism of injury remains unclear. HYPOTHESIS: Injury to a small-for-size liver graft is related to the changes of portal pressure and blood flow. MAIN OUTCOME MEASURES: Survival rates, portal hemodynamics, microcirculatory changes, and morphological changes (by light microscopy and electron microscopy). SETTING: A rat model of nonarterialized orthotopic liver transplantation comparing 2 groups of rats transplanted with whole grafts (100% of recipient liver weight) and small-for-size grafts (30% of recipient liver weight). RESULTS: Median survival of the rats with small-for-size grafts was 30 hours (range, 27-37 hours). During the first 15 minutes after reperfusion, mean arterial pressure of the small-for-size graft group was significantly lower than that of the whole graft group (10-minute: 100 vs 132 mm Hg, P =.04; 15-minute: 96 vs 127 mm Hg, P =.04). Portal pressure (in centimeters of water) of the small-for-size graft group was significantly higher in the first 20 minutes after reperfusion than the level before the anhepatic phase (5-minute: 15.1 vs 9.3, P =.02; 10-minute: 16.1 vs 9.3, P =.03; 15-minute, 13.5 vs 9.3, P =.03; 20-minute: 13.4 vs 9.3, P =.03) and was significantly higher than that of the whole graft group in the first 10 minutes after reperfusion (5-minute: 15.1 vs 9.6, P =.02; 10-minute: 16.1 vs 10.3, P =.04). Hepatic microcirculatory blood flow (in milliliters per minute per 100 g) was also significantly higher in the small-for-size graft group during the first 40 minutes after reperfusion (5-minute: 16.3 vs 9.3, P =.02; 10-minute: 14.9 vs 6.6, P =.02; 15-minute: 14.8 vs 5.5, P =.02; 20-minute: 13.1 vs 7.0, P =.02; 30-minute: 13.2 vs 8.8, P =.04; 40-minute: 14.6 vs 7.1, P =.02). Light and electron microscopy showed normal morphological features of whole graft up to 24 hours after reperfusion. The small-for-size graft, however, showed sinusoidal congestion, tremendous swelling of mitochondria of hepatocytes, irregular large gap of sinusoidal lining cells, and collapse of the space of Disse. CONCLUSIONS: In a rat model, the portal hemodynamic changes in small-for-size grafts are transient. Progressive damage of the graft may result from microcirculatory failure due to irreversible endothelial injury after reperfusion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archsurg.136.3.280

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 188

Metadata

Authors
Man, K.
Venue
Archives of Surgery
Published
2001-03-01
Volume
136
Issue
3
Pages
280
ISSN
0004-0010 (ISSN-L)
OpenAlex
W1978803498
Cited by
188
References
0
FWCI
9.32
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Liver Transplantation in Rats Using Small-for-Size Grafts: A Study of Hemodynamic and Morphological Changes. https://app.cochat.ai/papers/10.1001/archsurg.136.3.280
The paper
Man, K. (2001). Liver Transplantation in Rats Using Small-for-Size Grafts: A Study of Hemodynamic and Morphological Changes. Archives of Surgery. https://doi.org/10.1001/archsurg.136.3.280

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.