Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 226

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A Systematic Review of the Comparative Safety of Colloids

Barron, Michael E.·2004·Archives of Surgery

Abstract

HYPOTHESIS: Safety differences exist among colloids widely used for fluid management in acutely ill patients, as judged according to the comparative incidence of adverse events. DATA SOURCES: Colloid safety data for human subjects were sought, without language or time period restrictions, by means of computer searches of bibliographic and clinical trial databases, hand searches of medical journals and Index Medicus, inquiries with investigators and colloid suppliers, and examination of reference lists. Search terms included "colloids", "morbidity", and "mortality". STUDY SELECTION: Controlled trials, cohort studies, pharmacovigilance studies, and prior meta-analyses were independently selected by 2 unblinded investigators. Of 189 candidate studies, 113 were included, with safety data encompassing 1.54 x 10(6) patients and 1.09 x 10(8) colloid infusions. DATA EXTRACTION: Two unblinded investigators independently extracted data. Study limitations and confounding factors were tabulated. DATA SYNTHESIS: With albumin as the reference colloid, the incidence rate ratio for anaphylactoid reactions was 4.51 (95% confidence interval, 2.06-9.89) after hydroxyethyl starch administration, 2.32 (95% confidence interval, 1.21-4.45) after dextran, and 12.4 (95% confidence interval, 6.40-24.0) after gelatin. Pruritus occurrence was significantly increased by hydroxyethyl starch exposure (odds ratio, 1.78; 95% confidence interval, 1.23-2.58). Artificial colloid administration was consistently associated with coagulopathy and clinical bleeding, most frequently in cardiac surgery patients receiving hydroxyethyl starch. On the basis of large-scale pharmacovigilance study results, albumin infusion resulted in a low rate of both total adverse events (3.1 to 8.6 per 10(5) infusions) and serious adverse events (1.29 per 10(6) infusions). CONCLUSIONS: Significant safety differences exist among colloids. Therefore, conclusions regarding the clinical usefulness of colloids as a fluid class should be formed with caution.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archsurg.139.5.552

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 226

Metadata

Authors
Barron, M. E.
Venue
Archives of Surgery
Published
2004-05-05
Volume
139
Issue
5
Pages
552
ISSN
0004-0010 (ISSN-L)
OpenAlex
W2037511867
Cited by
226
References
1
FWCI
9.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Systematic Review of the Comparative Safety of Colloids. https://app.cochat.ai/papers/10.1001/archsurg.139.5.552
The paper
Barron, M. E. (2004). A Systematic Review of the Comparative Safety of Colloids. Archives of Surgery. https://doi.org/10.1001/archsurg.139.5.552

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.