Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 174

The DOI matches its Crossref record.

Increases in Intra-abdominal Pressure Affect Pulmonary Compliance

Obeid, Farouck · 1995 · Archives of Surgery

Abstract

OBJECTIVES: To determine the effect of increased intra-abdominal pressure (IAP) on pulmonary compliance and to determine an effective means to measure IAP. DESIGN: A prospective study. SETTING: An urban tertiary care hospital. PATIENTS: Twenty-six adult patients undergoing laparoscopic cholecystectomy. INTERVENTIONS: Intra-operative management of laparoscopic cholecystectomy requiring endotracheal intubation with general anesthesia, nasogastric and urinary bladder catheters, and position changes. Additional interventions included use of a rectal manometer and a respiratory pressure module inserted within the ventilator circuit. MAIN OUTCOME MEASURES: Correlation of changes in IAP with changes in dynamic pulmonary compliance, measured as tidal volume/(end inspiratory pressure--end expiratory pressure) and comparison of three different measurement techniques (bladder, rectal, and gastric) with a standard technique (insufflation pressure) in three different positions (supine, Trendelenburg's, and reverse Trendelenburg's). RESULTS: Compliance was significantly related to insufflation pressure (P < .001) by analysis of variance. In the gas insufflation model, the mean increment in bladder pressure reflected most closely the IAP increment in the supine position (5.7 vs 6 mm Hg) but not in the Trendelenburg (2.1 vs 6 mm Hg) and reverse Trendelenburg positions (3.4 vs 6 mm Hg). Rectal and gastric pressures were also position dependent and technically less reliable. CONCLUSIONS: Increased IAP has a major influence on pulmonary compliance (50% decrease at 16 mm Hg). Measurements of IAP by intraorgan manometry are position dependent and may not accurately reflect the intraperitoneal pressure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archsurg.1995.01430050094016

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 174

Metadata

Authors
Obeid, F.
Venue
Archives of Surgery
Published
1995-05-01
Volume
130
Issue
5
Pages
544
ISSN
0004-0010 (ISSN-L)
OpenAlex
W2088178412
Cited by
174
References
0
FWCI
4.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Increases in Intra-abdominal Pressure Affect Pulmonary Compliance. https://app.cochat.ai/papers/10.1001/archsurg.1995.01430050094016
The paper
Obeid, F. (1995). Increases in Intra-abdominal Pressure Affect Pulmonary Compliance. Archives of Surgery. https://doi.org/10.1001/archsurg.1995.01430050094016

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.