OBJECTIVE: To evaluate a closed-loop system providing continuous monitoring and strict control of perioperative blood glucose following pancreatic resection. DESIGN: Prospective, randomized clinical trial. PATIENTS: Thirty patients who had pancreatic resection for pancreatic neoplasm. INTERVENTIONS: Patients were prospectively randomized. Perioperative blood glucose levels were continuously monitored using an artificial endocrine pancreas (STG-22). Glucose levels were controlled using either the sliding scale method (sliding scale group, n = 13) or the artificial pancreas (artificial pancreas group, n = 17). MAIN OUTCOME MEASURES: Incidence of severe hypoglycemia (<40 mg/dL) during the intensive care period following pancreatic resection in patients monitored with the artificial pancreas. The secondary outcome measure was the total amount of insulin required for glycemic control in the first 18 hours after pancreatic resection in each patient group. RESULTS: In the sliding scale group, postoperative blood glucose levels rose initially before reaching a plateau of approximately 200 mg/dL between 4 and 6 hours after pancreatectomy. The levels remained high for 18 hours postoperatively. In the artificial pancreas group, blood glucose levels reduced steadily, reaching the target zone (80-110 mg/dL) by 6 hours after surgery. The total insulin dose administered per patient during the first postoperative 18 hours was significantly higher in the artificial pancreas group (mean [SD], 107 [109] IU) than the sliding scale group (8 [6] IU; P < .01). Neither group showed hypoglycemia. CONCLUSIONS: Perioperative use of an artificial endocrine pancreas to control pancreatogenic diabetes after pancreatic resection is an easy and effective way to maintain near-normal blood glucose levels. The artificial pancreas shows promise for use as insulin treatment for patients with pancreatogenic diabetes after pancreatic resection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archsurg.2009.176

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 79

Metadata

Authors
Okabayashi, T.
Venue
Archives of Surgery
Published
2009-10-01
Volume
144
Issue
10
Pages
933
ISSN
0004-0010 (ISSN-L)
OpenAlex
W2125750518
Cited by
79
References
4
FWCI
4.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.