PHYSIOLOGIC RELATIONSHIPS BETWEEN INTRATHORACIC, INTRASPINAL AND ARTERIAL PRESSURES
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In 1934 one of us with Brewer and Brotman1described an optical manometer which offered certain advantages over those in use at that time. The customary2rubber membrane carrying a flat mirror was discarded for a thin metal disk and a 0.5 diopter planoconvex lens silvered on the plane side. The new mirror design made it possible to lengthen the optical lever and to get photographic tracings of unusual clarity, and this with the simplest of optical arrangements. The disk (coin silver 0.0015 inch thick) increased the volume elasticity coefficient of the system to such a degree that it was possible to increase its effective mass 500 fold or more. In accordance with the mathematical principles laid down by Otto Frank3we were free from the limitations imposed by a small effective mass and could construct a manometer that was much more convenient, flexible and adaptable than
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Pressure Pulses in the Cardiovascular System
(1929) · Nature · doi:10.1038/124873b0 · Cited by 147
FACTORS IN THE CAUSATION OF DIFFERENTIAL BLOOD PRESSURE
Bazett, H. C. (1924) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1924.70.3.550 · Cited by 18
Cited by
Characterization of the oscillometric method for measuring indirect blood pressure
Geddes, L. A., Voelz, M., Combs, C., Reiner, D., & Babbs, C. F. (1982) · Annals of Biomedical Engineering · doi:10.1007/bf02367308 · Cited by 340
“It should be pointed out that auscultatory systolic pressure is slightly below true systolic pressure (7,12); therefore in man So may not overestimate arterial systolic pressure by the amount reported herein.”
BackgroundCardiovascular Adjustments to Gravitational Stress
Blomqvist, C. G., & Stone, H. L. (1983) · Comprehensive Physiology · doi:10.1002/cphy.cp020328 · Cited by 291
The peripheral pulse wave: Information overlooked
Murray, W. B., & Foster, P. A. (1996) · Journal of Clinical Monitoring · doi:10.1007/bf02077634 · Cited by 232
The Valsalva manoeuvre: physiology and clinical examples
Pstras, L., Thomaseth, K., Waniewski, J., Balzani, I., & Bellavere, F. (2016) · Acta Physiologica · doi:10.1111/apha.12639 · Cited by 188
“The concomitant variations in HR and arterial BP [the latter being both the effect and source of autonomic reflex responses (Eckberg 1980)] during and after the typical graded VM can be divided into four physiological phases (Hamilton et al. 1936).”
BackgroundInfluence of cigarette smoking on human autonomic function.
Niedermaier, O. N., Smith, M. L., Beightol, L. A., Zukowska-Grojec, Z., Goldstein, D. S., & Eckberg, D. L. (1993) · Circulation · doi:10.1161/01.cir.88.2.562 · Cited by 183
Aortocaval compression by the uterus in late human pregnancy
Bieniarz, J., Yoshida, T., Romero-Salinas, G., Curuchet, E., Caldeyro-Barcia, R., & Crottogini, J. J. (1969) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(16)34335-6 · Cited by 174
Tiecks, F. P., Lam, A. M., Matta, B. F., Strebel, S., Douville, C., & Newell, D. W. (1995) · Stroke · doi:10.1161/01.str.26.8.1386 · Cited by 173
Assessment of sympathetic index from the Valsalva maneuver
Novak, P. (2011) · Neurology · doi:10.1212/wnl.0b013e31821e5563 · Cited by 88
Effects of Acute Resistance Exercise on Arterial Stiffness in Young Men
Yoon, E. S., Jung, S. J., Cheun, S. K., Oh, Y. S., Kim, S. H., & Jae, S. Y. (2010) · Korean Circulation Journal · doi:10.4070/kcj.2010.40.1.16 · Cited by 83
Metadata
- Authors
- HAMILTON, W. F.
- Venue
- Journal of the American Medical Association
- Publisher
- American Medical Association (AMA)
- Published
- 1936-09-12
- Volume
- 107
- Issue
- 11
- Pages
- 853
- ISSN
- 0002-9955 (ISSN-L)
- OpenAlex
- W1993057582
- Cited by
- 277
- References
- 2
- FWCI
- 6.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.