CoChat

Treatment of Hypertension With an Implantable Electronic Device

Bilgutay, Aydin M. · 1965 · JAMA: The Journal of the American Medical Association
Cited by 84

The DOI matches its Crossref record.

Abstract

In some 90% to 95% of patients, the development of hypertension cannot be attributed to a definable cause.1One theory of the etiology of at least some forms of "essential hypertension" which has received experimental support is that of altered systemic pressure regulation by the "resetting" of the baroreceptor mechanisms.2-4 Kubicek et al2demonstrated experimentally the mechanism of resetting by showing a systemic blood-pressure rise within 20 hours of continuous electrical stimulation of the splanchnic nerves and observing that pulse rates were normal, indicating that baroreceptor mechanisms were no longer attempting to compensate. As stimulation was stopped, blood pressure fell and pulse rate increased, indicating that the baroreceptor mechanisms had been "reset" at higher levels and were acting to oppose pressure fall. McCubbin4showed that while the regulatory mechanism of the carotid sinus is active in both normotensive and hypertensive dogs, the baroreceptors of renal hypertensive

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.1965.03080080039010

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 84

Metadata

Authors
Bilgutay, A. M.
Venue
JAMA: The Journal of the American Medical Association
Published
1965-02-22
Volume
191
Issue
8
Pages
649
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2033859866
Cited by
84
References
0
FWCI
3.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Treatment of Hypertension With an Implantable Electronic Device. https://app.cochat.ai/papers/10.1001/jama.1965.03080080039010
The paper
Bilgutay, A. M. (1965). Treatment of Hypertension With an Implantable Electronic Device. JAMA: The Journal of the American Medical Association. https://doi.org/10.1001/jama.1965.03080080039010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.