Radio-Frequency Electrophrenic Respiration: Long-Term Application to a Patient With Primary Hypoventilation
The DOI matches its Crossref record, with a small difference in title or year; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Radio-frequency electrophrenic respiration (EPR) has been used successfully on a long-term intermittent basis to manage a patient with primary hypoventilation. The ability to use it only when desired, to adjust the amplitude of stimulation, and to control the rate of stimulation externally, has been made possible by use of the technique of radio-frequency transmission. Electrophrenic respiration by stimulation of one phrenic nerve has been carried out each night for ten months. Moderate fatigue of the stimulated diaghragm could be demonstrated after ten hours of stimulation. Further observation is required to determine if such fatigue is progressive. The future uses of radio-frequency electrophrenic respiration may include any condition of hypoventilation associated with an intact phrenic nerve and diaphragm. Whether its use will be of long-term benefit in the early stages of some hypoventilatory situations secondary to parenchymal disease is under study.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
The Lung. Clinical Physiology and Pulmonary Function Tests.
(1963) · Annals of Internal Medicine · doi:10.7326/0003-4819-58-3-557_2 · Cited by 239
Electrical Stimulation of Excitable Tissue by Radio-Frequency Transmission
Glenn, W. W. L., Hageman, J. H., & Mauro, A. (1964) · Annals of Surgery · doi:10.1097/00000658-196409000-00002 · Cited by 107
Sarnoff, S. J., SARNOFF, L. C., & Jl, W. (1951) · PubMed · Cited by 67
Electrophrenic respiration by radiof requency induction
van Heeckeren, D. W., & Glenn, W. W. L. (1966) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)43375-8 · Cited by 38
ELECTROPHRENIC RESPIRATION. III. MECHANISM OF THE INHIBITION OF SPONTANEOUS RESPIRATION
Sarnoff, S. J., Whittenberger, J. L., & Hardenbergh, E. (1948) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1948.155.2.203 · Cited by 37
Sarnoff, S. J., Gaensler, E. A., & Maloney, J. V. (1950) · PubMed · Cited by 36
Long-term, continuous electrostimulation of a peripheral nerve.
DeVilliers, R., Nosé, Y., Meier, W., & KANTROWITZ, A. R. (1964) · PubMed · Cited by 25
Jv, M., AFFELDT, J. E., Sarnoff, S. J., & Whittenberger, J. L. (1951) · PubMed · Cited by 24
Sarnoff, S. J., Maloney, J. V., & Whittenberger, J. L. (1950) · Annals of Surgery · doi:10.1097/00000658-195011000-00006 · Cited by 20
Chatfield, P. O., & Sarnoff, S. J. (1950) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1950.163.1.118 · Cited by 8
Cited by
Items 101–109 of 109
Diaphragm pacing in apneic quadriplegia with brain stem and high spinal cord injuries.
NAKAJIMA, K., & SHARKEY, P. C. (1990) · リハビリテーション医学 : 日本リハビリテーション医学会誌 · doi:10.2490/jjrm1963.27.374
[Diaphragm pacing in the treatment of central alveolar hypoventilation syndrome].
Yasuma, F. (1988) · PubMed
Schechter, D. C. (1978) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1978.tb03496.x
Pacing of the Diaphragm in Chronic Respiratory Insufficiency: Present Status
Glenn, W. W. L. (1985) · 人工臓器 · doi:10.11392/jsao1972.14.1799
Vincken, W., & de Boeck, H. (1990) · Update in intensive care and emergency medicine · doi:10.1007/978-3-642-84125-5_18
Spinal cord injury: the cost of mechanical ventilation versus phrenic nerve stimulation
Baer, G. A., & Beitzel, R. (2022) · British Journal of Neuroscience Nursing · doi:10.12968/bjnn.2022.18.3.134
Advancing Peripheral Nerve Interfaces in a Large Animal Model
Andreis, F. R. (2022) · VBN Forskningsportal (Aalborg Universitet) · doi:10.54337/aau478976327
Stimolazione frenica impiantata intratoracica: tecnica chirurgica
Pimpec‐Barthes, F. L., & Rivera, C. (2024) · EMC - Tecniche Chirurgiche Torace · doi:10.1016/s1288-3336(24)49609-x
Weiß, M. (2008) · Elektronische Hochschulschriften der LMU München (Ludwig-Maximilians-Universität München) · doi:10.5282/edoc.9517
Metadata
- Authors
- Judson, J. P.
- Corresponding author
- Judson, John P.
- ORCID
- Judson, John P.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 1968-03-18
- Volume
- 203
- Issue
- 12
- Pages
- 1033
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2050889244
- Semantic Scholar
- 153ef81f44ed65e0e1dcf95fceb83b54ab238e1a
- Cited by
- 103
- References
- 11
- Citations by year
- 2026: 1 · 2024: 4 · 2023: 2 · 2022: 4 · 2021: 3 · 2019: 1 · 2018: 2 · 2016: 5 · 2015: 3 · 2014: 1 · 2013: 1 · 2012: 3
- FWCI
- 4.52
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- JAMA (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
- Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Neuroscience of respiration and sleep
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Keywords
- phrenic nerve stimulation, diaphragm stimulation, intermittent stimulation, diaphragm fatigue, respiratory muscle fatigue, parenchymal lung disease
- MeSH terms
- Adult, Blood Gas Analysis, Electric Stimulation, Hematocrit, Humans, Hypoventilation, Male, Phrenic Nerve, Platinum, Radio Waves, Respiration, Respiratory Function Tests, Respiratory Insufficiency
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.