Polytetrafluoroethylene Graft Survival in Hemodialysis
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Expanded polytetrafluoroethylene (PTFE) graft fistulas are widely used as secondary vascular access for patients receiving long-term hemodialysis treatment. Sixty-seven grafts were implanted in 48 patients and followed for 12 to 51 months. Cumulative patency for all grafts at 12 months was 67% +/- 6%, at 24 months 50% +/- 7%, and at 48 months 43% +/- 9%. Graft survival rates were different when considering graft configuration and location. Forearm straight graft survival at 12 months was 35% +/- 13%, upper arm curved grafts 60% +/- 19%, and forearm looped grafts 78% +/- 7%. Complications that decreased graft survival were related to thrombosis (21%), infection (25%), and intimal hyperplasia at the venous anastomosis (34%). After reviewing our experience, we believe that the challenge of secondary vascular access has not been solved by PTFE grafts. This should stimulate the search for better grafts and techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum utilization of the life table method in analyzing survival
Cutler, S. J., & Ederer, F. (1958) · Journal of Chronic Diseases · doi:10.1016/0021-9681(58)90126-7 · Cited by 2,870
Chronic Hemodialysis Using Venipuncture and a Surgically Created Arteriovenous Fistula
Brescia, M. J., Cimino, J. E., Appel, K., & Hurwich, B. J. (1966) · New England Journal of Medicine · doi:10.1056/nejm196611172752002 · Cited by 1,883
Matched Elastic Properties and Successful Arterial Grafting
Walden, R. (1980) · Archives of Surgery · doi:10.1001/archsurg.1980.01380100018004 · Cited by 234
Management of dialysis fistula thrombosis
Bone, G. E., & Pomajzl, M. J. (1979) · The American Journal of Surgery · doi:10.1016/0002-9610(79)90319-2 · Cited by 51
Bacteremic infectability: A function of vascular graft material and design
Roon, A. J., MALONE, J. M., Moore, W. S., Bean, B., & Campagna, G. (1977) · Journal of Surgical Research · doi:10.1016/0022-4804(77)90031-2 · Cited by 41
Cited by
III. NKF-K/DOQI Clinical Practice Guidelines for Vascular Access: Update 2000
(2001) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(01)70007-8 · Cited by 806
Type of vascular access and mortality in U.S. hemodialysis patients
Dhingra, R. K., Young, E. W., Hulbert-Shearon, T. E., Leavey, S. F., & Port, F. K. (2001) · Kidney International · doi:10.1046/j.1523-1755.2001.00947.x · Cited by 769
Vascular access for hemodialysis
Schwab, S. J. (1999) · Kidney International · doi:10.1046/j.1523-1755.1999.00409.x · Cited by 564
Canadian Hemodialysis Morbidity Study
Churchill, D. N., Taylor, D. W., Cook, R. J., LaPlante, P., Barre, P., Cartier, P., Fay, W. P., Goldstein, M. B., Jindal, K., Mandin, H., et al. (1992) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(13)80002-9 · Cited by 540
Vascular Access for Hemodialysis Patency Rates and Results of Revision
PALDER, S. B., KIRKMAN, R. L., WHITTEMORE, A. D., HAKIM, R. M., LAZARUS, J. M., & TILNEY, N. L. (1985) · Annals of Surgery · doi:10.1097/00000658-198508000-00015 · Cited by 514
Metadata
- Authors
- Munda, R.
- Venue
- JAMA: The Journal of the American Medical Association
- Publisher
- American Medical Association (AMA)
- Published
- 1983-01-14
- Volume
- 249
- Issue
- 2
- Pages
- 219
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2021913298
- Cited by
- 210
- References
- 5
- FWCI
- 13.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.