Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 205

The DOI matches its Crossref record.

Computer-Based Interview for Screening Blood Donors for Risk of HIV Transmission

Open access
Locke, Steven E.·1992·JAMA: The Journal of the American Medical Association

Abstract

OBJECTIVE: To test the ability of a computer-based interview to detect factors related to the risk of the human immunodeficiency virus (HIV) among potential blood donors and to determine donor reactions to the use of the interview. DESIGN: A comparison of the rate of detection of HIV-related factors elicited by a computer interview with that obtained by standard American Red Cross procedures for assessment of donor suitability, including a randomized crossover trial in which the order of the two methods was reversed. Information obtained by the computer was not available to influence the use of blood components for transfusion. SETTING: The computer interview was administered to donors at an American Red Cross blood donor center and at a mobile blood drive at a hospital. SUBJECTS: Consecutive sample of 294 male and female blood donors 18 to 75 years of age. MAIN OUTCOME MEASURES: Subjects' responses to the computer-based interview as well as responses to the standard Red Cross written questionnaires and face-to-face interviews were used for donor assessment. RESULTS: The interview took an average of 8 minutes to complete. From among 272 donors who provided complete data, the computer identified 12 donors who reported either behaviors associated with a risk of HIV acquisition or symptoms compatible with the acquired immunodeficiency syndrome; none of these donors had been so identified either by routine written questionnaires or by face-to-face interviews used to screen potential blood donors. Only one of the 12 identified donors used the confidential unit exclusion procedure to prevent use of his donated unit. The rate of elicitation of HIV-related factors by the computer interview was 12 (4.4%) of 272 (95% confidence interval [CI], 2.3% to 7.6%), compared with two (0.13%) of 1536 (95% confidence upper bound, 0.28%) using the standard Red Cross procedure (P less than .0001). Tests for antibodies to HIV were negative in blood samples from all of the 272 subjects studied. The subjects enjoyed the computer interview and judged it to be more private than the standard donor assessment method. They also predicted that donors would be more honest with the computer interview than with a human interviewer. CONCLUSIONS: Computer-based screening elicits more HIV-related factors in the health histories of blood donors than do the standard questionnaire and interviewing methods currently in use. Computer-based screening is also acceptable to blood donors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.1992.03490100099034

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 205

Metadata

Authors
Locke, S. E.
Venue
JAMA: The Journal of the American Medical Association
Published
1992-09-09
Volume
268
Issue
10
Pages
1301
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2021153657
Cited by
205
References
0
FWCI
20.47
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Computer-Based Interview for Screening Blood Donors for Risk of HIV Transmission. https://app.cochat.ai/papers/10.1001/jama.1992.03490100099034
The paper
Locke, S. E. (1992). Computer-Based Interview for Screening Blood Donors for Risk of HIV Transmission. JAMA: The Journal of the American Medical Association. https://doi.org/10.1001/jama.1992.03490100099034

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.