Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 169

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Impact of First-Responder Defibrillation in an Urban Emergency Medical Services System

Kellermann, Arthur L. · 1993 · JAMA: The Journal of the American Medical Association

Abstract

OBJECTIVE: To evaluate the impact of adding first-responder defibrillation by fire-fighters to an existing advanced life-support emergency medical services system. DESIGN: Nonrandomized, controlled clinical trial with periodic crossover. SETTING: Memphis, Tenn, a city of 610,337 people, which is served by a fire department-based emergency medical services system. All city ambulances provide advanced life support. PATIENTS: Adult victims of out-of-hospital cardiac arrest due to heart disease. INTERVENTION: Twenty of 40 participating engine companies were equipped with an automated external defibrillator and ordered to apply it immediately in all cases of cardiac arrest. The other 20 companies were ordered to start cardiopulmonary resuscitation (CPR) immediately and wait for paramedics to arrive. Every 75 days, group roles were reversed. Care otherwise proceeded according to 1986 American Heart Association guidelines. MAIN OUTCOME MEASURES: Return of spontaneous circulation in the field, survival to hospital admission, survival to hospital discharge, and neurological status at discharge. RESULTS: During the 39-month study interval, 879 patients were treated by a project engine company. Four hundred thirty-one (49%) of these were found in ventricular fibrillation. Bystander CPR was started in only 12% of cases. Overall, firefighters reached the scene a mean of 2.5 minutes faster than simultaneously dispatched paramedics. Although our automated external defibrillators proved to be reliable and efficacious for terminating ventricular fibrillation and pulseless ventricular tachycardia, patients treated by an automated external defibrillator-equipped engine company were no more likely than CPR-treated controls to be resuscitated (32% vs 34%, respectively), to survive to hospital admission (31% vs 29%), or to survive to hospital discharge (14% vs 10%). Neurological outcomes were also similar in the two treatment groups. CONCLUSIONS: In a fast-response, urban emergency medical services system served by paramedics, the impact of adding first-responder defibrillation appears to be small. Early defibrillation alone cannot overcome low community rates of bystander CPR. Careful attention to every link in the "chain of survival" is needed to achieve optimal rates of survival after cardiac arrest.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.1993.03510140068031

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 169

Metadata

Authors
Kellermann, A. L.
Venue
JAMA: The Journal of the American Medical Association
Published
1993-10-13
Volume
270
Issue
14
Pages
1708
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2021105189
Cited by
169
References
1
FWCI
13.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of First-Responder Defibrillation in an Urban Emergency Medical Services System. https://app.cochat.ai/papers/10.1001/jama.1993.03510140068031
The paper
Kellermann, A. L. (1993). Impact of First-Responder Defibrillation in an Urban Emergency Medical Services System. JAMA: The Journal of the American Medical Association. https://doi.org/10.1001/jama.1993.03510140068031

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.