The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The Use and Clinical Importance of a Substrate-Specific Electrode for Rapid Determination of Blood Lactate Concentrations
Abstract
OBJECTIVE: To determine the validity and clinical importance of a newly developed amperometric, enzymatic, substrate-specific electrode for the rapid measurement of circulating lactate concentrations. DESIGN: A prospective multiexperiment study. SETTING: The critical care medicine research laboratory, intensive care unit (ICU), emergency department (ED), and general wards of a university-affiliated hospital. PATIENTS: A total of 1218 patients and control subjects were studied on one or more occasions. INTERVENTIONS: Blood lactate concentrations, descriptive data, physiological parameters, and outcome results were determined in various patient populations. MAIN OUTCOME MEASURES AND RESULTS: Experiment 1: Lactate determinations performed with the new substrate-specific electrode were compared with two laboratory reference methods. Blood samples from 80 ICU patients and 165 ED patients formed the basis of this first experiment. There was excellent agreement between the test instrument and the two reference methods as reflected by bias (with reference method 1, 0.19 mmol/L; reference method 2, 0.09 mmol/L), precision (with reference method 1, +/- 0.47 mmol/L; reference method 2, +/- 0.34 mmol/L), and correlation data (with reference method 1, r = .92; reference method 2, r = .98). Experiment 2: The new test microchemistry instrument was used to analyze blood samples from 927 patients. The mean (SE) blood lactate concentrations in the various patient populations were 1.26 (0.04) mmol/L for control subjects (n = 85), 1.52 (0.03) mmol/L for general ward patients (n = 489; P < .001 vs normal subjects), 2.34 (0.15) mmol/L for ICU patients (n = 180; P < .001 vs normal subjects and general ward patients), and 2.44 (0.15) mmol/L for ED patients (n = 173; P < .001 vs normal subjects and general ward patients). None of the normal subjects and only one (0.2%) of 489 nonhypotensive general ward patients had a blood lactate value greater than 4 mmol/L. Circulating lactate concentrations greater than 4 mmol/L were 98.2% specific in predicting the need for hospital admission in patients presenting to the ED. Furthermore, lactate concentrations greater than 4 mmol/L were 96% specific in predicting mortality in hospitalized nonhypotensive patients. Experiment 3: Blood samples from 46 hypotensive ICU and ED patients and from 353 nonhypotensive ICU and ED patients (the latter samples were derived from experiment 2) were analyzed. A statistically significant difference was noted between the mean (SE) lactate concentration in hypotensive patients in the ICU and ED (4.75 [0.75] mmol/L) when compared with nonhypotensive ICU and ED patients (2.28 [0.10] mmol/L; P < .001). Furthermore, blood lactate values greater than 4 mmol/L were 87.5% specific in predicting mortality in hypotensive patients. CONCLUSIONS: Lactate determinations performed using the new test instrument are precise and accurate. Blood lactate concentrations greater than 4 mmol/L are unusual in normal and noncritically ill hospitalized patients and warrant concern. In hospitalized (non-ICU) nonhypotensive subjects, as well as in critically ill patients, a blood lactate concentration greater than 4 mmol/L may portend a poor prognosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Early lactate clearance is associated with improved outcome in severe sepsis and septic shock*
Nguyen, H. B., Rivers, E. P., Knoblich, B. P., Jacobsen, G., Muzzin, A., Ressler, J. A., & Tomlanovich, M. C. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000132904.35713.a7 · Cited by 1,228
Serum lactate is associated with mortality in severe sepsis independent of organ failure and shock*
Mikkelsen, M. E., Miltiades, A. N., Gaieski, D. F., Goyal, M., Fuchs, B. D., Shah, C. V., Bellamy, S. L., & Christie, J. D. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e31819fcf68 · Cited by 999
Jansen, T. C., van Bommel, J., Schoonderbeek, F. J., Sleeswijk Visser, S. J., van der Klooster, J. M., Lima, A. P., Willemsen, S. P., & Bakker, J. (2010) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200912-1918oc · Cited by 894
Serum Lactate as a Predictor of Mortality in Emergency Department Patients with Infection
Shapiro, N. I., Howell, M. D., Talmor, D., Nathanson, L. A., Lisbon, A., Wolfe, R. E., & Weiss, J. W. (2005) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2004.12.006 · Cited by 754
Biosensors in clinical chemistry
D'Orazio, P. (2003) · Clinica Chimica Acta · doi:10.1016/s0009-8981(03)00241-9 · Cited by 524
Metadata
- Authors
- Aduen, J.
- Venue
- JAMA: The Journal of the American Medical Association
- Publisher
- American Medical Association (AMA)
- Published
- 1994-12-07
- Volume
- 272
- Issue
- 21
- Pages
- 1678
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2003857210
- Cited by
- 209
- References
- 1
- FWCI
- 8.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Use and Clinical Importance of a Substrate-Specific Electrode for Rapid Determination of Blood Lactate Concentrations. https://app.cochat.ai/papers/10.1001/jama.1994.03520210062033
- The paper
- Aduen, J. (1994). The Use and Clinical Importance of a Substrate-Specific Electrode for Rapid Determination of Blood Lactate Concentrations. JAMA: The Journal of the American Medical Association. https://doi.org/10.1001/jama.1994.03520210062033
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.