CoChat

Optic nerve decompression surgery for nonarteritic anterior ischemic optic neuropathy (NAION) is not effective and may be harmful.

Dickersin, Kay · 1995 · JAMA: The Journal of the American Medical Association

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

Objective. —To assess the safety and efficacy of optic nerve decompression surgery compared with careful follow-up alone in patients with nonarteritic anterior ischemic optic neuropathy (NAION). Design. —The Ischemic Optic Neuropathy Decompression Trial (IONDT) is a randomized, single-masked, multicenter trial. Setting. —Twenty-five US clinical centers. Participants. —The IONDT ceased recruitment on October 20, 1994, on the recommendation of its Data and Safety Monitoring Committee. The preliminary results presented herein are based on data as of September 8,1994, from 244 patients with NAION and visual acuity of 20/64 or worse. One hundred twenty-five patients had been randomized to careful follow-up, and 119 had been randomized to surgery, with 91 and 95, respectively, having completed 6 months of follow-up. Intervention. —Patients in the surgery group received optic nerve decompression surgery and follow-up ophthalmologic examinations; those in the careful follow-up group received ophthalmologic examinations at the same times as the surgery group. Main Outcome Measures. —Gain or loss of three or more lines of visual acuity on the New York Lighthouse chart at 6 months after randomization, as measured by a technician masked to treatment assignment. Results. —Patients assigned to surgery did no better when compared with patients assigned to careful follow-up regarding improved visual acuity of three or more lines at 6 months: 32.6% of the surgery group improved compared with 42.7% of the careful follow-up group. The odds ratio (OR) for three or more lines better, adjusted for baseline visual acuity and diabetes, was 0.74 (95% confidence interval [CI], 0.39 to 1.38). Patients receiving surgery had a significantly greater risk of losing three or more lines of vision at 6 months: 23.9% in the surgery group worsened compared with 12.4% in the careful follow-up group. The 6-month adjusted OR for three or more lines worse was 1.96 (95% CI, 0.87 to 4.41). No difference in treatment effect was observed between patients with progressive NAION and all others. Conclusion. —Results from the IONDT indicate that optic nerve decompression surgery for NAION is not effective, may be harmful, and should be abandoned. The spontaneous improvement rate is better than previously reported. (JAMA. 1995;273:625-632)

Overview

Integrity signals

Registry

Crossref · 10.1001/jama.1995.03520320035038

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 17 references

Cited by

See all 451

Metadata

Authors
Dickersin, K.
Corresponding author
Dickersin, Kay
Venue
JAMA: The Journal of the American Medical Association
Published
1995-02-22
Volume
273
Issue
8
Pages
625
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2132661211
Cited by
393
References
17
Citations by year
2026: 8 · 2025: 13 · 2024: 7 · 2023: 7 · 2022: 11 · 2021: 6 · 2020: 7 · 2019: 10 · 2018: 14 · 2017: 11 · 2016: 16 · 2015: 14 · 2014: 11 · 2013: 21 · 2012: 14
FWCI
19.40
Type
journal article
Language
en
Open access
closed
Locations
JAMA (publishedVersion)
Topics
  • Health Sciences › Medicine › Ophthalmology › Glaucoma and retinal disorders
  • Health Sciences › Medicine › Clinical Neurology › Acute Ischemic Stroke Management
  • Health Sciences › Medicine › Surgery › Intraoperative Neuromonitoring and Anesthetic Effects
Keywords
nonarteritic anterior ischemic optic neuropathy, visual acuity outcomes, surgical safety, visual field defects

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optic nerve decompression surgery for nonarteritic anterior ischemic optic neuropathy (NAION) is not effective and may be harmful. https://app.cochat.ai/papers/10.1001/jama.1995.03520320035038
The paper
Dickersin, K. (1995). Optic nerve decompression surgery for nonarteritic anterior ischemic optic neuropathy (NAION) is not effective and may be harmful. JAMA: The Journal of the American Medical Association. https://doi.org/10.1001/jama.1995.03520320035038

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.