The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Quality of Traditional Surveillance for Public Reporting of Nosocomial Bloodstream Infection Rates
Open accessAbstract
CONTEXT: Central line-associated bloodstream infection (BSI) rates, determined by infection preventionists using the Centers for Disease Control and Prevention (CDC) surveillance definitions, are increasingly published to compare the quality of patient care delivered by hospitals. However, such comparisons are valid only if surveillance is performed consistently across institutions. OBJECTIVE: To assess institutional variation in performance of traditional central line-associated BSI surveillance. DESIGN, SETTING, AND PARTICIPANTS: We performed a retrospective cohort study of 20 intensive care units among 4 medical centers (2004-2007). Unit-specific central line-associated BSI rates were calculated for 12-month periods. Infection preventionists, blinded to study participation, performed routine prospective surveillance using CDC definitions. A computer algorithm reference standard was applied retrospectively using criteria that adapted the same CDC surveillance definitions. MAIN OUTCOME MEASURES: Correlation of central line-associated BSI rates as determined by infection preventionist vs the computer algorithm reference standard. Variation in performance was assessed by testing for institution-dependent heterogeneity in a linear regression model. RESULTS: Forty-one unit-periods among 20 intensive care units were analyzed, representing 241,518 patient-days and 165,963 central line-days. The median infection preventionist and computer algorithm central line-associated BSI rates were 3.3 (interquartile range [IQR], 2.0-4.5) and 9.0 (IQR, 6.3-11.3) infections per 1000 central line-days, respectively. Overall correlation between computer algorithm and infection preventionist rates was weak (ρ = 0.34), and when stratified by medical center, point estimates for institution-specific correlations ranged widely: medical center A: 0.83; 95% confidence interval (CI), 0.05 to 0.98; P = .04; medical center B: 0.76; 95% CI, 0.32 to 0.93; P = .003; medical center C: 0.50, 95% CI, -0.11 to 0.83; P = .10; and medical center D: 0.10; 95% CI -0.53 to 0.66; P = .77. Regression modeling demonstrated significant heterogeneity among medical centers in the relationship between computer algorithm and expected infection preventionist rates (P < .001). The medical center that had the lowest rate by traditional surveillance (2.4 infections per 1000 central line-days) had the highest rate by computer algorithm (12.6 infections per 1000 central line-days). CONCLUSIONS: Institutional variability of infection preventionist rates relative to a computer algorithm reference standard suggests that there is significant variation in the application of standard central line-associated BSI surveillance definitions across medical centers. Variation in central line-associated BSI surveillance practice may complicate interinstitutional comparisons of publicly reported central line-associated BSI rates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Intervention to Decrease Catheter-Related Bloodstream Infections in the ICU
Pronovost, P., Needham, D., Berenholtz, S., Sinopoli, D., Chu, H., Cosgrove, S., Sexton, B., Hyzy, R., Welsh, R., Roth, G., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa061115 · Cited by 4,387
The GAAP in Quality Measurement and Reporting
Pronovost, P. J., Miller, M., & Wachter, R. M. (2007) · JAMA · doi:10.1001/jama.298.15.1800 · Cited by 92
Cited by
Marschall, J., Mermel, L. A., Fakih, M., Hadaway, L., Kallen, A., O’Grady, N. P., Pettis, A. M., Rupp, M. E., Sandora, T., Maragakis, L. L., et al. (2014) · Infection Control & Hospital Epidemiology · doi:10.1086/676533 · Cited by 550
Buetti, N., Marschall, J., Drees, M., Fakih, M. G., Hadaway, L., Maragakis, L. L., Monsees, E., Novosad, S., O’Grady, N. P., Rupp, M. E., et al. (2022) · Infection Control & Hospital Epidemiology · doi:10.1017/ice.2022.87 · Cited by 475
Bion, J., Richardson, A., Hibbert, P., Beer, J., Abrusci, T., McCutcheon, M., Cassidy, J., Eddleston, J., Gunning, K., Bellingan, G., et al. (2013) · BMJ Quality & Safety · doi:10.1136/bmjqs-2012-001325 · Cited by 300
Gratwohl, A. (2012) · Bone Marrow Transplantation · doi:10.1038/bmt.2011.110 · Cited by 293
Surveillance Bias in Outcomes Reporting
Haut, E. R. (2011) · JAMA · doi:10.1001/jama.2011.822 · Cited by 262
Metadata
- Authors
- Lin, M. Y., Hota, B., Khan, Y. M., Woeltje, K. F., Borlawsky, T. B., Doherty, J. A., Stevenson, K. B., Weinstein, R. A., Trick, W. E., & CDC Prevention Epicenter Program, F. T.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2010-11-10
- Volume
- 304
- Issue
- 18
- Pages
- 2035-41
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2001815564
- Cited by
- 168
- References
- 2
- FWCI
- 14.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quality of Traditional Surveillance for Public Reporting of Nosocomial Bloodstream Infection Rates. https://app.cochat.ai/papers/10.1001/jama.2010.1637
- The paper
- Lin, M. Y., Hota, B., Khan, Y. M., Woeltje, K. F., Borlawsky, T. B., Doherty, J. A., Stevenson, K. B., Weinstein, R. A., Trick, W. E., & CDC Prevention Epicenter Program, F. T. (2010). Quality of Traditional Surveillance for Public Reporting of Nosocomial Bloodstream Infection Rates. JAMA. https://doi.org/10.1001/jama.2010.1637
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.