Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 209

The DOI matches its Crossref record.

Radiation Exposure From Medical Imaging: Time to Regulate?

Brenner, David J., Hricak, Hedvig·2010·JAMA

Abstract

THE AVERAGE RADIATION DOSE TO WHICH PERSONS IN the United States are exposed has doubled over the past 30 years. Although the average dose from natural background sources has not changed, the average radiation dose from medical imaging has increased more than 6-fold. Medical imaging now contributes about 50% of the overall radiation dose to the US population, compared with about 15% in 1980. The largest contributor to this dramatic increase in population radiation exposure is the computed tomography (CT) scan. In 1980 fewer than 3 million CT scans were performed, but the annual number now approaches 80 million and is increasing by approximately 10% per year. Because CT scanning involves acquiring multiple images, CT scans result in a far larger radiation dose to the patient than most other common radiographic procedures such as chest x-rays or mammograms. Although CT is responsible for most of the rapid increase in population exposure from medical imaging, other radiographic imaging and nuclear medicine procedures are also increasing rapidly, particularly in cardiology. Newer radiographic imaging modalities such as positron-emission tomography CT (PET/CT), singlephoton emission CT (SPECT/CT), and, potentially, CT screening of asymptomatic patients are likely to increase the population radiation exposure still further. This increase in radiological imaging and nuclear medicine certainly has revolutionized medical practice in a fundamental and highly beneficial manner. However, like almost all medical procedures, medical imaging has benefits and risks, and the goal is to provide the public with the optimal benefit/risk balance. The risks associated with radiation doses typical of CT scans are not yet fully quantified, but there is persuasive evidence, at the doses relevant to CT, that the risks of radiation carcinogenesis are real, although small for any individual. The concern arises when an increasingly large population is exposed to small individual risks. Regardless of the actual magnitude, these population risks would undoubtedly be reduced if radiation doses were optimized for each procedure and if medically unnecessary imaging were minimized. Although it is impossible to imagine contemporary medicine without modern medical imaging, there are serious issues of quality control, training, and, particularly of overutilization that can best be addressed through national legislation. In fact, radiation exposure from medical radiographic imaging is comparatively unregulated; this is in striking contrast to radiation exposure in occupational settings, which is stringently regulated despite it contributing a far smaller population exposure. The current US situation is that quality control and quality assurance for x-ray machines and facilities are the responsibility of individual states, and a variety of different standards and rules are in place; accreditation programs, through the American College of Radiology, are currently voluntary. With a single exception, US federal agencies have no legislative authority to regulate usage of x-ray devices. The exception is the 1992 Mammography Quality Standards Act (MQSA), which regulates quality standards at all US mammography facilities. While mammography is an important component of the radiological imaging armory, it contributes much less than 1% to the overall population dose from medical imaging. This patchwork of regulations in the United States stands in contrast to the situation in Europe, where a uniform European medical exposure directive was introduced in 1997, providing wide-ranging requirements that each member state must implement. Should the United States move in this direction or is the current status quo adequate? There are several issues that need to be addressed to optimize the benefit-risk balance for medical imaging. The first is quality control and assurance. Recent incidents in which several hundred patients received radiation overdoses from CT scans suggest that quality control is, at the least, uneven in US medical imaging facilities. Moreover, radiation doses from identical CT procedures can vary by as much as 10-fold from facility to facility. Some recent initiatives by the US Food and Drug Administration, as well as by the American College of Radiology and the Radiological Society of North America, are designed to improve medical imaging quality control. However these initiatives are largely

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.2010.973

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 209

Metadata

Authors
Brenner, D. J., & Hricak, H.
Venue
JAMA
Published
2010-07-14
Volume
304
Issue
2
Pages
208
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2061622865
Cited by
209
References
0
FWCI
18.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Radiation Exposure From Medical Imaging: Time to Regulate? https://app.cochat.ai/papers/10.1001/jama.2010.973
The paper
Brenner, D. J., & Hricak, H. (2010). Radiation Exposure From Medical Imaging: Time to Regulate? JAMA. https://doi.org/10.1001/jama.2010.973

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.