Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 367

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Effect of a Cerebral Protection Device on Brain Lesions Following Transcatheter Aortic Valve Implantation in Patients With Severe Aortic Stenosis: The CLEAN-TAVI Randomized Clinical Trial

Open access
Haussig, Stephan, Mangner, Norman, Dwyer, Michael G., Lehmkuhl, Lukas, Lücke, Christian, Woitek, Felix, Holzhey, David M., Mohr, Friedrich W, Gutberlet, Matthias, Zivadinov, Robert, Schuler, Gerhard, Linke, Axel·2016·JAMA

Abstract

IMPORTANCE: Stroke remains a major predictor of mortality after transcatheter aortic valve implantation (TAVI). Cerebral protection devices might reduce brain injury as determined by diffusion-weighted magnetic resonance imaging (DWMRI). OBJECTIVE: To determine the effect of a cerebral protection device on the number and volume of cerebral lesions in patients undergoing TAVI. DESIGN, SETTING, AND PARTICIPANTS: Investigator-initiated, single center, blinded, randomized clinical trial in higher-risk patients with severe aortic stenosis undergoing TAVI at the University of Leipzig Heart Center. Brain MRI was performed at baseline, 2 days, and 7 days after TAVI. Between April 2013 and June 2014, patients were randomly assigned to undergo TAVI with a cerebral protection device (filter group) or without a cerebral protection device (control group). The last 1-month follow-up occurred in July 2014. INTERVENTIONS: TAVI with or without a cerebral protection device (filter system). MAIN OUTCOMES AND MEASURES: The primary end point was the numerical difference in new positive postprocedure DWMRI brain lesions at 2 days after TAVI in potentially protected territories. The first hierarchical secondary outcome was the difference in volume of new lesions after TAVI in potentially protected territories. RESULTS: Among the 100 enrolled patients, mean (SD) age was 80.0 (5.1) years in the filter group (n = 50) and 79.1 (4.1) years in the control group (n = 50), and the mean (SD) procedural risk scores (logistic EuroScores) were 16.4% (10.0%) in the filter group and 14.5% (8.7%) in the control group. For the primary end point, the number of new lesions was lower in the filter group, 4.00 (interquartile range [IQR], 3.00-7.25) vs 10.00 (IQR, 6.75-17.00) in the control group (difference, 5.00 [IQR, 2.00-8.00]; P < .001). For the first hierarchical secondary end point, new lesion volume after TAVI was lower in the filter group (242 mm3 [95% CI, 159-353]) vs in the control group (527 mm3 [95% CI, 364-830]) (difference, 234 mm3 [95% CI, 91-406]; P = .001). Considering adverse events, 1 patient in the control group died prior to the 30-day visit. Life-threatening hemorrhages occurred in 1 patient in the filter group and 1 in the control group. Major vascular complications occurred in 5 patients in the filter group and 6 patients in the control group. One patient in the filter group and 5 in the control group had acute kidney injury, and 3 patients in the filter group had a thoracotomy. CONCLUSIONS AND RELEVANCE: Among patients with severe aortic stenosis undergoing TAVI, the use of a cerebral protection device reduced the frequency of ischemic cerebral lesions in potentially protected regions. Larger studies are needed to assess the effect of cerebral protection device use on neurological and cognitive function after TAVI and to devise methods that will provide more complete coverage of the brain to prevent new lesions. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT01833052.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.2016.10302

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 367

Metadata

Authors
Haussig, S., Mangner, N., Dwyer, M. G., Lehmkuhl, L., Lücke, C., Woitek, F., Holzhey, D. M., Mohr, F. W., Gutberlet, M., Zivadinov, R., Schuler, G., & Linke, A.
Venue
JAMA
Published
2016-08-09
Volume
316
Issue
6
Pages
592
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2482392026
Cited by
367
References
22
FWCI
33.62
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of a Cerebral Protection Device on Brain Lesions Following Transcatheter Aortic Valve Implantation in Patients With Severe Aortic Stenosis: The CLEAN-TAVI Randomized Clinical Trial. https://app.cochat.ai/papers/10.1001/jama.2016.10302
The paper
Haussig, S., Mangner, N., Dwyer, M. G., Lehmkuhl, L., Lücke, C., Woitek, F., Holzhey, D. M., Mohr, F. W., Gutberlet, M., Zivadinov, R., Schuler, G., & Linke, A. (2016). Effect of a Cerebral Protection Device on Brain Lesions Following Transcatheter Aortic Valve Implantation in Patients With Severe Aortic Stenosis: The CLEAN-TAVI Randomized Clinical Trial. JAMA. https://doi.org/10.1001/jama.2016.10302

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.