Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 329

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Will This Hemodynamically Unstable Patient Respond to a Bolus of Intravenous Fluids?

Bentzer, Peter, Griesdale, Donald E., Boyd, John, MacLean, Kelly, Sirounis, Demetrios, Ayas, Najib T.·2016·JAMA

Abstract

IMPORTANCE: Fluid overload occurring as a consequence of overly aggressive fluid resuscitation may adversely affect outcome in hemodynamically unstable critically ill patients. Therefore, following the initial fluid resuscitation, it is important to identify which patients will benefit from further fluid administration. OBJECTIVE: To identify predictors of fluid responsiveness in hemodynamically unstable patients with signs of inadequate organ perfusion. DATA SOURCES AND STUDY SELECTION: Search of MEDLINE and EMBASE (1966 to June 2016) and reference lists from retrieved articles, previous reviews, and physical examination textbooks for studies that evaluated the diagnostic accuracy of tests to predict fluid responsiveness in hemodynamically unstable adult patients who were defined as having refractory hypotension, signs of organ hypoperfusion, or both. Fluid responsiveness was defined as an increase in cardiac output following intravenous fluid administration. DATA EXTRACTION: Two authors independently abstracted data (sensitivity, specificity, and likelihood ratios [LRs]) and assessed methodological quality. A bivariate mixed-effects binary regression model was used to pool the sensitivities, specificities, and LRs across studies. RESULTS: A total of 50 studies (N = 2260 patients) were analyzed. In all studies, indices were measured before assessment of fluid responsiveness. The mean prevalence of fluid responsiveness was 50% (95% CI, 42%-56%). Findings on physical examination were not predictive of fluid responsiveness with LRs and 95% CIs for each finding crossing 1.0. A low central venous pressure (CVP) (mean threshold <8 mm Hg) was associated with fluid responsiveness (positive LR, 2.6 [95% CI, 1.4-4.6]; pooled specificity, 76%), but a CVP greater than the threshold made fluid responsiveness less likely (negative LR, 0.50 [95% CI, 0.39-0.65]; pooled sensitivity, 62%). Respiratory variation in vena cava diameter measured by ultrasound (distensibility index >15%) predicted fluid responsiveness in a subgroup of patients without spontaneous respiratory efforts (positive LR, 5.3 [95% CI, 1.1-27]; pooled specificity, 85%). Patients with less vena cava distensibility were not as likely to be fluid responsive (negative LR, 0.27 [95% CI, 0.08-0.87]; pooled sensitivity, 77%). Augmentation of cardiac output or related parameters following passive leg raising predicted fluid responsiveness (positive LR, 11 [95% CI, 7.6-17]; pooled specificity, 92%). Conversely, the lack of an increase in cardiac output with passive leg raising identified patients unlikely to be fluid responsive (negative LR, 0.13 [95% CI, 0.07-0.22]; pooled sensitivity, 88%). CONCLUSIONS AND RELEVANCE: Passive leg raising followed by measurement of cardiac output or related parameters may be the most useful test for predicting fluid responsiveness in hemodynamically unstable adults. The usefulness of respiratory variation in the vena cava requires confirmatory studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.2016.12310

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 329

Metadata

Authors
Bentzer, P., Griesdale, D. E., Boyd, J., MacLean, K., Sirounis, D., & Ayas, N. T.
Venue
JAMA
Published
2016-09-27
Volume
316
Issue
12
Pages
1298
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2527672914
Cited by
329
References
6
FWCI
25.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Will This Hemodynamically Unstable Patient Respond to a Bolus of Intravenous Fluids? https://app.cochat.ai/papers/10.1001/jama.2016.12310
The paper
Bentzer, P., Griesdale, D. E., Boyd, J., MacLean, K., Sirounis, D., & Ayas, N. T. (2016). Will This Hemodynamically Unstable Patient Respond to a Bolus of Intravenous Fluids? JAMA. https://doi.org/10.1001/jama.2016.12310

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.