Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 208

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Association Between Transcatheter Aortic Valve Replacement and Early Postprocedural Stroke

Open access
Huded, Chetan P., Tuzcu, E. Murat, Krishnaswamy, Amar, Mick, Stephanie L., Kleiman, Neal S., Svensson, Lars G., Carroll, John, Thourani, Vinod H., Kirtane, Ajay J., Manandhar, Pratik, Kosinski, Andrzej S., Vemulapalli, Sreekanth, Kapadia, Samir R. · 2019 · JAMA

Abstract

Importance: Reducing postprocedural stroke is important to improve the safety of transcatheter aortic valve replacement (TAVR). Objective: This study evaluated the trends of stroke occurring within 30 days after the procedure during the first 5 years TAVR was used in the United States, the association of stroke with 30-day mortality, and the association of medical therapy with 30-day stroke risk. Design, Setting, and Participants: Retrospective cohort study including 101 430 patients who were treated with femoral and nonfemoral TAVR at 521 US hospitals in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapies Registry from November 9, 2011, through May 31, 2017. Thirty-day follow-up ended June 30, 2017. Exposures: TAVR. Main Outcomes and Measures: The rates of 30-day transient ischemic attack and stroke were assessed. Association of stroke with 30-day mortality and association of antithrombotic medical therapies with postdischarge 30-day stroke were assessed with a Cox proportional hazards model and propensity-score matching, respectively. Results: Among 101 430 patients included in the study (median age, 83 years [interquartile range {IQR}, 76-87 years]; 47 797 women [47.1%]; and 85 147 patients [83.9%] treated via femoral access), 30-day postprocedure follow-up data was assessed in all patients. At day 30, there were 2290 patients (2.3%) with a stroke of any kind (95% CI, 2.2%-2.4%), and 373 patients (0.4%) with transient ischemic attacks (95% CI, 0.3%-0.4%) . During the study period, 30-day stroke rates were stable without an increasing or decreasing trend in all patients (P for trend = .22) and in the large femoral access subgroup (P trend = .47). Among cases of stroke within 30 days, 1119 strokes (48.9%) occurred within the first day and 1567 (68.4%) within 3 days following TAVR. The occurrence of stroke was associated with a significant increase in 30-day mortality: 383 patients (16.7%) of 2290 who had a stroke vs 3662 patients (3.7%) of 99 140 who did not have a stroke died (P < .001; risk-adjusted hazard ratio [HR], 6.1 [95% CI, 5.4-6.8]; P < .001). After propensity-score matching, 30-day stroke risk was not associated with whether patients in the femoral cohort were (0.55%) or were not (0.52%) treated with dual antiplatelet therapy at hospital discharge (HR, 1.04; 95% CI, 0.74-1.46) nor was it associated with whether patients in the nonfemoral cohort were (0.71%) or were not (0.69%) treated with dual antiplatelet therapy (HR, 1.02; 95% CI, 0.54-1.95). Similarly, 30-day stroke risk was not associated with whether patients in the femoral cohort were (0.57%) or were not (0.55) treated with oral anticoagulant therapy at hospital discharge (HR, 1.03; 95% CI, 0.73-1.46) nor was it associated with whether patients in the nonfemoral cohort were (0.75%) or were not (0.82%) treated with an oral anticoagulant (HR, 0.93; 95% CI, 0.47-1.83). Conclusions and Relevance: Between 2011 and 2017, the rate of 30-day stroke following transcatheter aortic valve replacement in a US registry population remained stable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.2019.7525

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 208

Metadata

Authors
Huded, C. P., Tuzcu, E. M., Krishnaswamy, A., Mick, S. L., Kleiman, N. S., Svensson, L. G., Carroll, J., Thourani, V. H., Kirtane, A. J., Manandhar, P., Kosinski, A. S., Vemulapalli, S., & Kapadia, S. R.
Venue
JAMA
Published
2019-06-18
Volume
321
Issue
23
Pages
2306
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2950108666
Cited by
208
References
3
FWCI
12.55
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Association Between Transcatheter Aortic Valve Replacement and Early Postprocedural Stroke. https://app.cochat.ai/papers/10.1001/jama.2019.7525
The paper
Huded, C. P., Tuzcu, E. M., Krishnaswamy, A., Mick, S. L., Kleiman, N. S., Svensson, L. G., Carroll, J., Thourani, V. H., Kirtane, A. J., Manandhar, P., Kosinski, A. S., Vemulapalli, S., & Kapadia, S. R. (2019). Association Between Transcatheter Aortic Valve Replacement and Early Postprocedural Stroke. JAMA. https://doi.org/10.1001/jama.2019.7525

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.