Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 164

The DOI matches its OpenAlex record.

Likelihood ratios for modern screening mammography. Risk of breast cancer based on age and mammographic interpretation

Karla M. Kerlikowske · 1996 · JAMA

Abstract

OBJECTIVE: To determine the sensitivity, specificity, and likelihood ratios (LRs) for modern screening mammography by decade of age and mammographic interpretation. DESIGN: Cross-sectional. SETTING: Nine counties in northern California. PARTICIPANTS: A total of 26,057 women aged 30 years and older who underwent a total of 41,747 first and subsequent screening mammographic examinations at the Mobile Mammography Screening Program of the University of California, San Francisco, from April 1985 to September 1991. MEASUREMENTS: Breast cancer risk profile, 2 standard mammographic views per breast, and follow-up of abnormal and normal mammograms of contacting women's physicians and by linkage to the regional Surveillance, Epidemiology, and End Results tumor registry. False-negative examinations were normal examinations that occurred within 13 months of a diagnosis of invasive breast cancer or ductal carcinoma in situ. RESULTS: The sensitivity of first screening mammography increased with age: 77.3% for ages 30 to 39 years, 86.7% for ages 40 to 49 years, 93.6% for ages 50 to 59 years, 94.1% for ages 60 to 69 years, and 91.2% for ages 70 years and older (P = .04). Specificity was similar for all ages, ranging from 92.6% to 95.2%. Of all abnormal first screening examinations, 92.9% were reported as "additional evaluation needed." The LRs for that category ranged from 5.2 to 8.8 and did not vary with age. Based on the risk of breast cancer before mammography, which increases with age, the risk of breast cancer after mammography associated with these LRs were 0.01 for ages 30 to 39 years, 0.02 for ages 40 to 49 years, 0.05 for ages 50 to 59 years, 0.07 for ages 60 to 69 years, and 0.07 for ages 70 years and older. The LRs for mammography reported as "suspicious for malignancy" ranged from 88 to 144 and did not vary across age groups. These LRs were associated with a risk of breast cancer about 10 times greater than when mammography was reported as "additional evaluation needed." CONCLUSION: Most abnormal first screening mammography are interpreted as "additional evaluation needed" and are associated with LRs of about 7. Given this low LR, the risk of breast cancer after mammography is primarily influenced by a woman's age-specific risk of breast cancer before mammography. The LRs for screening mammography interpreted as "suspicious for malignancy" are high (about 124) and are associated with a substantial increase in the risk of breast cancer irrespective of age, but these interpretations comprise only a small proportion of abnormal mammography.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

OpenAlex · 10.1001/jama.276.1.39

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 164

Metadata

Authors
Kerlikowske, K. M.
Venue
JAMA
Publisher
American Medical Association
Published
1996-07-03
Volume
276
Issue
1
Pages
39-43
ISSN
0002-9955 (ISSN-L)
OpenAlex
W2057611483
Cited by
164
References
0
FWCI
10.95
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Likelihood ratios for modern screening mammography. Risk of breast cancer based on age and mammographic interpretation. https://app.cochat.ai/papers/10.1001/jama.276.1.39
The paper
Kerlikowske, K. M. (1996). Likelihood ratios for modern screening mammography. Risk of breast cancer based on age and mammographic interpretation. JAMA. https://doi.org/10.1001/jama.276.1.39

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.