The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Minimally Invasive and Robotic Surgery
Abstract
Advances in surgery have focused on minimizing the invasiveness of surgical procedures, such that a significant paradigm shift has occurred for some procedures in which surgeons no longer directly touch or see the structures on which they operate. Advancements in video imaging, endoscope technology, and instrumentation have made it possible to convert many procedures in many surgical specialties from open surgeries to endoscopic ones. The use of computers and robotics promises to facilitate complex endoscopic procedures by virtue of voice control over the networked operating room, enhancement of dexterity to facilitate microscale operations, and development of virtual simulator trainers to enhance the ability to learn new complex operations. Future research will focus on delivery of diagnostic and therapeutic modalities through natural orifices in which investigation is under remote control and navigation, so that truly "noninvasive" surgery will be a reality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robotically‐assisted laparoscopic radical prostatectomy
Binder, J., & Kramer, W. (2001) · BJU International · doi:10.1046/j.1464-410x.2001.00115.x · Cited by 749
Comparison of Conventional Anterior Surgery and Laparoscopic Surgery for Inguinal-Hernia Repair
Liem, M. S. L., van der Graaf, Y., van Steensel, C. J., Boelhouwer, R. U., Clevers, G.-J., Meijer, W. S., Stassen, L. P. S., Vente, J. P., Weidema, W. F., Schrijvers, A. J. P., et al. (1997) · New England Journal of Medicine · doi:10.1056/nejm199705293362201 · Cited by 541
A Steady-Hand Robotic System for Microsurgical Augmentation
Taylor, R., Jensen, P., Whitcomb, L., Barnes, A., Kumar, R., Stoianovici, D., Gupta, P., Wang, Z., Dejuan, E., & Kavoussi, L. (1999) · The International Journal of Robotics Research · doi:10.1177/02783649922067807 · Cited by 528
Inflammatory response after coronary revascularization with or without cardiopulmonary bypass
Ascione, R., Lloyd, C. T., Underwood, M. J., Lotto, A. A., Pitsis, A. A., & Angelini, G. D. (2000) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(00)01152-8 · Cited by 495
Port-access coronary artery bypass grafting: A proposed surgical method
Stevens, J. H., Burdon, T. A., Peters, W. S., Siegel, L. C., Pompili, M. F., Vierra, M. A., St. Goar, F. G., Ribakove, G. H., Mitchell, R. S., & Reitz, B. A. (1996) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(96)70308-2 · Cited by 277
A study of instrument motion in retinal microsurgery
Riviere, C. N., & Jensen, P. S. (2002) · Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143) · doi:10.1109/iembs.2000.900667 · Cited by 70 · cited 1×
“One such example is retinal vein cannulation with a needle for administration of a local therapy for retinal vein thrombosis; this technique (involving cannulation of a 100-micron structure) would not be possible without the dexterity enhancement of robotic assistance.(20) Another focus on dexterity enhancement is in…”
Cited by
Microrobots for Minimally Invasive Medicine
Nelson, B. J., Kaliakatsos, I. K., & Abbott, J. J. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-010510-103409 · Cited by 1,968
Micro/nanorobots for biomedicine: Delivery, surgery, sensing, and detoxification
Li, J., Esteban-Fernández de Ávila, B., Gao, W., Zhang, L., & Wang, J. (2017) · Science Robotics · doi:10.1126/scirobotics.aam6431 · Cited by 1,565
Transatlantic robot-assisted telesurgery
Marescaux, J., Leroy, J., Gagner, M., Rubino, F., Mutter, D., Vix, M., Butner, S. E., & Smith, M. K. (2001) · Nature · doi:10.1038/35096636 · Cited by 1,080
A review of tactile sensing technologies with applications in biomedical engineering
Tiwana, M. I., Redmond, S. J., & Lovell, N. H. (2012) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2012.02.051 · Cited by 721
Hydrogel interfaces for merging humans and machines
Yuk, H., Wu, J., & Zhao, X. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00483-4 · Cited by 661
Metadata
- Authors
- Mack, M. J.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2001-02-07
- Volume
- 285
- Issue
- 5
- Pages
- 568
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2145359186
- Cited by
- 545
- References
- 6
- FWCI
- 23.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.