Diagnostic Accuracy of a Bedside D-dimer Assay and Alveolar Dead-Space Measurement for Rapid Exclusion of Pulmonary Embolism: A Multicenter Study
The DOI matches its Crossref record.
Abstract
CONTEXT: A previous study suggested that the combination of a normal D-dimer assay and normal alveolar dead-space fraction is a highly sensitive screening test for pulmonary embolism (PE). OBJECTIVE: To determine if the combination of a normal alveolar dead-space fraction (volume of alveolar dead space/tidal volume </=20%) and a normal whole-blood agglutination D-dimer assay can exclude PE in emergency department (ED) patients. DESIGN: Prospective, noninterventional study conducted in 1998-1999. Study data were obtained prior to standard testing for PE, consisting of radionuclide lung scanning or contrast-enhanced computed tomography and 6-month follow-up plus selective use of venous ultrasonography and pulmonary angiography. Imaging studies were interpreted by blinded observers. SETTING: Six urban teaching hospitals in the United States. PATIENTS: A total of 380 hemodynamically stable ED patients aged 18 years or older with suspected acute PE. MAIN OUTCOME MEASURES: Sensitivity and specificity for PE with a positive test defined as having either alveolar dead-space fraction or D-dimer assay results abnormal. Alveolar dead-space fraction was determined by subtracting airway dead space from physiological dead space (determined using the modified Bohr equation) and D-dimer assay, assayed at bedside using 20 microL of arterial blood. RESULTS: Pulmonary embolism was diagnosed in 64 patients (16.8%), of those 20 had an abnormal D-dimer assay result, 3 had an abnormal alveolar dead-space fraction, 40 had abnormal results in both, and 1 had normal results for both tests. The sensitivity for diagnosis of PE was 98.4% (95% confidence interval [CI], 91.6%-100.0%). Among the 316 patients without PE, both D-dimer and dead-space results were normal in 163, for a specificity of 51.6% (95% CI, 46.1%-57.1%). Posterior probability of PE with normal results on both tests was 0.75% (95% CI, 0%-3.4%). CONCLUSION: In this multicenter study of ED patients, a normal D-dimer assay result plus a normal alveolar dead-space fraction was associated with a low prevalence of PE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The STARD Statement for Reporting Studies of Diagnostic Accuracy: Explanation and Elaboration
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Moher, D., Rennie, D., de Vet, H. C. W., & Lijmer, J. G. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00012-w1 · Cited by 1,124
“Patients were prospectively enrolled during times the investigators or study associates were available (30).”
d-Dimer for the Exclusion of Acute Venous Thrombosis and Pulmonary Embolism: A Systematic Review
Stein, P. D., Hull, R. D., Patel, K. C., Olson, R. E., Ghali, W. A., Brant, R., Biel, R. K., Bharadia, V., & Kalra, N. K. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-8-200404200-00005 · Cited by 800
Reitsma, J. B., Rutjes, A. W. S., Khan, K. S., Coomarasamy, A., & Bossuyt, P. M. (2009) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.02.005 · Cited by 405
Brown, M. D., Rowe, B. H., Reeves, M. J., Bermingham, J. M., & Goldhaber, S. Z. (2002) · Annals of Emergency Medicine · doi:10.1067/mem.2002.124755 · Cited by 173
Clinical review: Respiratory monitoring in the ICU - a consensus of 16
Brochard, L., Martin, G. S., Blanch, L., Pelosi, P., Belda, F. J., Jubran, A., Gattinoni, L., Mancebo, J., Ranieri, V. M., Richard, J.-C. M., et al. (2012) · Critical Care · doi:10.1186/cc11146 · Cited by 160
“When volumetric capnography is used as a bedside technique, the association of a normal D-dimer assay result plus a normal Vdalv is a highly sensitive screening test to rule out the diagnosis of pulmonary embolism [15].”
Method
Metadata
- Authors
- Kline, J. A.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2001-02-14
- Volume
- 285
- Issue
- 6
- Pages
- 761
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W1986486333
- Cited by
- 128
- References
- 0
- FWCI
- 7.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.