Computed Tomographic Colonography (Virtual Colonoscopy): A Multicenter Comparison With Standard Colonoscopy for Detection of Colorectal Neoplasia
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
CONTEXT: Conventional colonoscopy is the best available method for detection of colorectal cancer; however, it is invasive and not without risk. Computed tomographic colonography (CTC), also known as virtual colonoscopy, has been reported to be reasonably accurate in the diagnosis of colorectal neoplasia in studies performed at expert centers. OBJECTIVE: To assess the accuracy of CTC in a large number of participants across multiple centers. DESIGN, SETTING, AND PARTICIPANTS: A nonrandomized, evaluator-blinded, noninferiority study design of 615 participants aged 50 years or older who were referred for routine, clinically indicated colonoscopy in 9 major hospital centers between April 17, 2000, and October 3, 2001. The CTC was performed by using multislice scanners immediately before standard colonoscopy; findings at colonoscopy were reported before and after segmental unblinding to the CTC results. MAIN OUTCOME MEASURES: The sensitivity and specificity of CTC and conventional colonoscopy in detecting participants with lesions sized at least 6 mm. Secondary outcomes included detection of all lesions, detection of advanced lesions, possible technical confounders, participant preferences, and evidence for increasing accuracy with experience. RESULTS: A total of 827 lesions were detected in 308 of 600 participants who underwent both procedures; 104 participants had lesions sized at least 6 mm. The sensitivity of CTC for detecting participants with 1 or more lesions sized at least 6 mm was 39.0% (95% confidence interval [CI], 29.6%-48.4%) and for lesions sized at least 10 mm, it was 55.0% (95% CI, 39.9%-70.0%). These results were significantly lower than those for conventional colonoscopy, with sensitivities of 99.0% (95% CI, 97.1%->99.9%) and 100%, respectively. A total of 496 participants were without any lesion sized at least 6 mm. The specificity of CTC and conventional colonoscopy for detecting participants without any lesion sized at least 6 mm was 90.5% (95% CI, 87.9%-93.1%) and 100%, respectively, and without lesions sized at least 10 mm, 96.0% (95% CI, 94.3%-97.6%) and 100%, respectively. Computed tomographic colonography missed 2 of 8 cancers. The accuracy of CTC varied considerably between centers and did not improve as the study progressed. Participants expressed no clear preference for either technique. CONCLUSIONS: Computed tomographic colonography by these methods is not yet ready for widespread clinical application. Techniques and training need to be improved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prevention of Colorectal Cancer by Colonoscopic Polypectomy
Winawer, S. J., Zauber, A. G., Ho, M. N., O'Brien, M. J., Gottlieb, L. S., Sternberg, S. S., Waye, J. D., Schapiro, M., Bond, J. H., Panish, J. F., et al. (1993) · New England Journal of Medicine · doi:10.1056/nejm199312303292701 · Cited by 4,592
Computed Tomographic Virtual Colonoscopy to Screen for Colorectal Neoplasia in Asymptomatic Adults
Pickhardt, P. J., Choi, J. R., Hwang, I., Butler, J. A., Puckett, M. L., Hildebrandt, H. A., Wong, R. K., Nugent, P. A., Mysliwiec, P. A., & Schindler, W. R. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa031618 · Cited by 1,972
Use of Colonoscopy to Screen Asymptomatic Adults for Colorectal Cancer
Lieberman, D. A., Weiss, D. G., Bond, J. H., Ahnen, D. J., Garewal, H., Harford, W. V., Provenzale, D., Sontag, S., Schnell, T., Durbin, T. E., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200007203430301 · Cited by 1,815
Colonoscopic miss rates of adenomas determined by back-to-back colonoscopies
Rex, D., Cutler, C., Lemmel, G., Rahmani, E., Clark, D., Helper, D., Lehman, G., & Mark, D. (1997) · Gastroenterology · doi:10.1016/s0016-5085(97)70214-2 · Cited by 1,553
Self-citationA Comparison of Virtual and Conventional Colonoscopy for the Detection of Colorectal Polyps
Fenlon, H. M., Nunes, D. P., Schroy, P. C., Barish, M. A., Clarke, P. D., & Ferrucci, J. T. (1999) · New England Journal of Medicine · doi:10.1056/nejm199911113412003 · Cited by 746
Colorectal Neoplasia: Performance Characteristics of CT Colonography for Detection in 300 Patients
Yee, J., Akerkar, G. A., Hung, R. K., Steinauer-Gebauer, A. M., Wall, S. D., & McQuaid, K. R. (2001) · Radiology · doi:10.1148/radiology.219.3.r01jn40685 · Cited by 489
Johnson, C. D., Harmsen, W. S., Wilson, L. A., Maccarty, R. L., Welch, T. J., Ilstrup, D. M., & Ahlquist, D. A. (2003) · Gastroenterology · doi:10.1016/s0016-5085(03)00894-1 · Cited by 351
Optimization of CT Colonography Technique: Prospective Trial in 180 Patients
Fletcher, J. G., Johnson, C. D., Welch, T. J., MacCarty, R. L., Ahlquist, D. A., Reed, J. E., Harmsen, W. S., & Wilson, L. A. (2000) · Radiology · doi:10.1148/radiology.216.3.r00au41704 · Cited by 342
Patient preferences for CT colonography, conventional colonoscopy, and bowel preparation
Ristvedt, S. (2003) · The American Journal of Gastroenterology · doi:10.1016/s0002-9270(02)06024-0 · Cited by 199
Pineau, B. C., Paskett, E. D., Chen, G. J., Espeland, M. A., Phillips, K., Han, J. P., Mikulaninec, C., & Vining, D. J. (2003) · Gastroenterology · doi:10.1016/s0016-5085(03)00885-0 · Cited by 192
Self-citationSpinzi, G., Belloni, G., Martegani, A., Sangiovanni, A., FAVERO, C. D., & Minoli, G. (2001) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2001.03550.x · Cited by 157
MR Colonography with Barium-based Fecal Tagging: Initial Clinical Experience
Lauenstein, T. C., Goehde, S. C., Ruehm, S. G., Holtmann, G., & Debatin, J. F. (2002) · Radiology · doi:10.1148/radiol.2231010887 · Cited by 138
Akerkar, G. A., Yee, J., Hung, R. K., et al. (2001) · Gastrointestinal Endoscopy · doi:10.1067/mge.2001.117595 · Cited by 128
Colorectal Cancer Screening: Clinical Applications
Walsh, J. M. E., & Terdiman, J. P. (2003) · JAMA · doi:10.1001/jama.289.10.1297 · Cited by 126
Detection of colorectal lesions with virtual computed tomographic colonography
Laghi, A., Iannaccone, R., Carbone, I., Catalano, C., Giulio, E. D., Schillaci, A., & Passariello, R. (2002) · The American Journal of Surgery · doi:10.1016/s0002-9610(01)00857-1 · Cited by 118
Postić, G., Lewin, D., Bickerstaff, C., & Wallace, M. B. (2002) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2002.07128.x · Cited by 93
On the sample size for one‐sided equivalence of sensitivities based upon McNemar's test
Lü, Y., & Bean, J. A. (1995) · Statistics in Medicine · doi:10.1002/sim.4780141611 · Cited by 91
Virtual colonoscopy compared with conventional colonoscopy: a developing technology
Mendelson, R., Wood, C. J., Rosenberg, M. S., Foster, N. M., Edwards, J. T., & Forbes, G. M. (2000) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.2000.tb139298.x · Cited by 59
Is virtual colonoscopy ready for widespread application?
Rex, D. K. (2003) · Gastroenterology · doi:10.1016/s0016-5085(03)00960-0 · Cited by 35
Self-citationDurkalski, V., Palesch, Y. Y., Pineau, B. C., Vining, D. J., & Cotton, P. B. (2002) · Controlled Clinical Trials · doi:10.1016/s0197-2456(02)00232-5 · Cited by 15
Self-citationCash, B. D., Schoenfeld, P., & Rex, D. K. (2003) · Clinical Gastroenterology and Hepatology · doi:10.1053/cgh.2003.50021 · Cited by 14
Self-citation
Cited by
Levin, B., Lieberman, D. A., McFarland, B., Andrews, K. S., Brooks, D., Bond, J., Dash, C., Giardiello, F. M., Glick, S., Johnson, D., et al. (2008) · Gastroenterology · doi:10.1053/j.gastro.2008.02.002 · Cited by 2,990
Self-citationLieberman, D. A., Rex, D. K., Winawer, S. J., Giardiello, F. M., Johnson, D. A., & Levin, T. R. (2012) · Gastroenterology · doi:10.1053/j.gastro.2012.06.001 · Cited by 1,892
Self-citationLevin, B., Lieberman, D. A., McFarland, B., Smith, R. A., Brooks, D., Andrews, K. S., Dash, C., Giardiello, F. M., Glick, S., Levin, T. R., et al. (2008) · CA: A Cancer Journal for Clinicians · doi:10.3322/ca.2007.0018 · Cited by 1,801
Self-citationAccuracy of CT Colonography for Detection of Large Adenomas and Cancers
Johnson, C. D., Chen, M.-H., Toledano, A. Y., Heiken, J. P., Dachman, A., Kuo, M. D., Menias, C. O., Siewert, B., Cheema, J. I., Obregon, R. G., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0800996 · Cited by 1,036
Self-citationWinawer, S. J., Zauber, A. G., Fletcher, R. H., Stillman, J. S., O’Brien, M. J., Levin, B., Smith, R. A., Lieberman, D. A., Burt, R. W., Levin, T. R., et al. (2006) · Gastroenterology · doi:10.1053/j.gastro.2006.03.012 · Cited by 761
Self-citation
Metadata
- Authors
- Cotton, P. B., Durkalski, V. L., Pineau, B. C., Palesch, Y. Y., Mauldin, P. D., Hoffman, B., Vining, D. J., Small, W. C., Affronti, J., Rex, D., Kopecky, K. K., Ackerman, S., Burdick, J. S., Brewington, C., Turner, M. A., Zfass, A., Wright, A. R., Iyer, R. B., Lynch, P., Sivak, M. V., & Butler, H.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2004-04-14
- Volume
- 291
- Issue
- 14
- Pages
- 1713
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2144198467
- Cited by
- 673
- References
- 21
- FWCI
- 43.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.