The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Arterial Puncture Closing Devices Compared With Standard Manual Compression After Cardiac Catheterization: Systematic Review and Meta-analysis
Abstract
CONTEXT: Arterial puncture closing devices (APCDs) were developed to replace standard compression at the puncture site and to shorten bed rest following percutaneous coronary intervention. OBJECTIVE: To assess the safety and efficacy of APCDs (Angioseal, Vasoseal, Duett, Perclose, Techstar, Prostar) compared with standard manual compression in patients undergoing coronary angiography or percutaneous vascular interventions. DATA SOURCES: A systematic literature search of MEDLINE (1966-January 2003), EMBASE (1989-January 2003), PASCAL (1996-January 2003), BIOSIS (1990-January 2003), and CINHAL (1982-January 2003) databases and the Cochrane Central Register of Controlled Trials for relevant articles in any language. STUDY SELECTION: Included randomized controlled trials reporting vascular complications at the puncture site (hematoma, bleeding, arteriovenous fistula, pseudoaneurysm) and efficacy (time to hemostasis, time to ambulation, time to discharge from hospital). DATA EXTRACTION: Two reviewers abstracted the data independently and in duplicate. Disagreements were resolved by discussion among at least 3 reviewers. The most important criteria were adequacy of allocation concealment, whether the analysis was according to the intention-to-treat principle, and if person assessing the outcome was blinded to intervention group. Random-effects models were used to pool the data. DATA SYNTHESIS: Thirty trials met the selection criteria and included up to 4000 patients. When comparing any APCD with standard compression, the relative risk (RR) of groin hematoma was 1.14 (95% confidence interval [CI], 0.86-1.51; P =.35); bleeding, 1.48 (95% CI, 0.88-2.48; P =.14); developing an arteriovenous fistula, 0.83 (95% CI, 0.23-2.94; P =.77); and developing a pseudoaneurysm at the puncture site, 1.19 (95% CI, 0.75-1.88; P =.46). Time to hemostasis was shorter in the group with APCD compared with standard compression (mean difference, 17 minutes; range, 14-19 minutes), but there was a high degree of heterogeneity among studies. Only 2 studies explicitly reported allocation concealment, blinded outcome assessment, and intention-to-treat analysis. When limiting analyses to only trials that used explicit intention-to-treat approaches, APCDs were associated with a higher risk of hematoma (RR, 1.89; 95% CI, 1.13-3.15) and a higher risk of pseudoaneurysm (RR, 5.40; 95% CI, 1.21-24.5). CONCLUSIONS: Based on this meta-analysis of 30 randomized trials, many of poor methodological quality, there is only marginal evidence that APCDs are effective and there is reason for concern that these devices may increase the risk of hematoma and pseudoaneurysm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bias in meta-analysis detected by a simple, graphical test
Egger, M., Smith, G. D., Schneider, M., & Minder, C. (1997) · BMJ · doi:10.1136/bmj.315.7109.629 · Cited by 56,722
Quantifying heterogeneity in a meta‐analysis
Higgins, J. P. T., & Thompson, S. G. (2002) · Statistics in Medicine · doi:10.1002/sim.1186 · Cited by 36,763
Cha, M., Eastwaad, S., Hartan, R., Maher, D., Olkin, I., Pitkin, R., Rennie, D., Schulz, K. F., Simel, D. L., & Straup, D. F. (1996) · Cited by 737
Omoigui, N. A., Califf, R. M., Pieper, K. S., Keeler, G. P., O’Hanesian, M. A., Berdan, L. G., Mark, D. B., Talley, J. D., & Topol, E. J. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00263-4 · Cited by 110
Cited by
WRITING COMMITTEE MEMBERS*, O’Gara, P. T., Kushner, F. G., Ascheim, D. D., Casey, D. E., Chung, M. K., de Lemos, J. A., Ettinger, S. M., Fang, J. C., Fesmire, F. M., et al. (2013) · Circulation · doi:10.1161/cir.0b013e3182742cf6 · Cited by 4,725
Writing Committee Members, Levine, G. N., Bates, E. R., Blankenship, J. C., Bailey, S. R., Bittl, J. A., Cercek, B., Chambers, C. E., Ellis, S. G., Guyton, R. A., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31823ba622 · Cited by 3,289
2013 ACCF/AHA Guideline for the Management of ST-Elevation Myocardial Infarction
O'Gara, P. T., Kushner, F. G., Ascheim, D. D., Casey, D. E., Chung, M. K., de Lemos, J. A., Ettinger, S. M., Fang, J. C., Fesmire, F. M., Franklin, B. A., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.019 · Cited by 2,625
WRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.170815 · Cited by 2,218
2011 ACCF/AHA/SCAI Guideline for Percutaneous Coronary Intervention
Levine, G. N., Bates, E. R., Blankenship, J. C., Bailey, S. R., Bittl, J. A., Cercek, B., Chambers, C. E., Ellis, S. G., Guyton, R. A., Hollenberg, S. M., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.007 · Cited by 2,164
Metadata
- Authors
- Koreny, M., Riedmüller, E., Nikfardjam, M., Siostrzonek, P., & Müllner, M.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2004-01-21
- Volume
- 291
- Issue
- 3
- Pages
- 350
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W1980147374
- Cited by
- 559
- References
- 4
- FWCI
- 24.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Arterial Puncture Closing Devices Compared With Standard Manual Compression After Cardiac Catheterization: Systematic Review and Meta-analysis. https://app.cochat.ai/papers/10.1001/jama.291.3.350
- The paper
- Koreny, M., Riedmüller, E., Nikfardjam, M., Siostrzonek, P., & Müllner, M. (2004). Arterial Puncture Closing Devices Compared With Standard Manual Compression After Cardiac Catheterization: Systematic Review and Meta-analysis. JAMA. https://doi.org/10.1001/jama.291.3.350
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.