Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 183

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Screening Healthy Infants for Iron Deficiency Using Reticulocyte Hemoglobin Content

Ullrich, Christina·2005·JAMA

Abstract

CONTEXT: Current clinical practice relies on hemoglobin to detect iron deficiency, which misses infants not yet anemic and places them at higher risk for neurocognitive impairment. Reticulocyte hemoglobin content (CHr) has never been compared with hemoglobin for screening healthy infants. OBJECTIVES: To evaluate CHr for detecting iron deficiency without anemia in healthy 9- to 12-month-old infants and to compare CHr with hemoglobin in screening for iron deficiency in this population. A secondary objective was to explore the association between CHr and subsequent development of anemia. DESIGN, SETTING, AND PATIENTS: A prospective observational cohort study of 202 healthy 9- to 12-month-old infants from an urban, hospital-based, primary care clinic in Boston, Mass, who were screened for iron deficiency between June 2000 and April 2003, and followed up for a median of 5.6 months. MAIN OUTCOME MEASURES: Iron deficiency (transferrin saturation <10%) and anemia (hemoglobin <11 g/dL). RESULTS: Of 202 infants enrolled, 23 (11.4%) had iron deficiency and 6 (3%) had iron deficiency and anemia. Iron-deficient and non-iron-deficient infants had significantly different values for all measured hematological and biochemical markers for iron deficiency. Optimal CHr cutoff for detecting iron deficiency was 27.5 pg (sensitivity, 83% and specificity, 72%); a hemoglobin level of less than 11 g/dL resulted in a sensitivity of 26% and a specificity of 95%. Reticulocyte hemoglobin content was more accurate overall than hemoglobin was for detecting iron deficiency (area under the receiver operating characteristic curve, 0.85 vs 0.73; P = .007). A CHr of less than 27.5 pg without anemia at initial screening was associated with subsequent anemia when screened again in the second year of life (risk ratio, 9.1; 95% confidence interval, 1.04-78.9; P = .01). CONCLUSIONS: A CHr of less than 27.5 pg is a more accurate hematological indicator of iron deficiency compared with hemoglobin of less than 11 g/dL in these healthy 9- to 12-month-old infants. Further studies are warranted to determine whether CHr should be the preferred screening tool in the early detection of iron deficiency in infants.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.294.8.924

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 183

Metadata

Authors
Ullrich, C.
Venue
JAMA
Published
2005-08-24
Volume
294
Issue
8
Pages
924
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2054100895
Cited by
183
References
2
FWCI
5.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Screening Healthy Infants for Iron Deficiency Using Reticulocyte Hemoglobin Content. https://app.cochat.ai/papers/10.1001/jama.294.8.924
The paper
Ullrich, C. (2005). Screening Healthy Infants for Iron Deficiency Using Reticulocyte Hemoglobin Content. JAMA. https://doi.org/10.1001/jama.294.8.924

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.